F. Timing/Dialing Options
There are six positions in the timing/dialing options. To program these options, enter the six desired timing/dialing num-
bers followed by #18. The six available timing/dialing options are defined as follows:
Factory Default Setting: 2 + 3 + 4 + 1 + 1 + 1
Talk/Listen Delay
Call Length
Silence Time Out
Dial Next Number on Ring No Answer
Dial Next Number on Busy
Pulse Dial Speed
Setting A - Talk/Listen Delay
This feature selects switching time between talk and listen modes (VOX switching time).
Use chart at the right. *
Setting B - Call Length Time Out
This feature selects the maximum length of time that calls can be connected.
Programmable in increments of 1 minute up to a maximum of 9 minutes (Touch Tones 1 -
9). Program 0 in this location to disable the call length time out. With the call length dis-
abled, the 1600A series phone must rely on a CPC signal, busy signal, silence or return to
dial tone to hang-up. Use chart at the right. *
Setting C - Silence Time Out
This feature selects the length of time that calls will remain connected without voice activ-
ity. Programmable in increments of 10 seconds up to a maximum of 90 seconds (Touch
Tones 1 - 9). To disable the silence time out, program 0 in this location. Use chart at the
far right. *
Setting D - Dial Next Number on Ring No Answer
If enabled and a ring-no-answer is detected, the 1600A series
phone will dial the next programmed speed dial number, and con-
tinue to cycle through the emergency numbers until a call is com-
pleted.
This feature is disabled in the factory default setting.
Setting E - Dial Next Number on Busy
If enabled and a busy is detected, the 1600A series phone will dial the next pro-
grammed speed dial number, and continue to cycle through the emergency num-
bers until a call is completed. *
default setting. If the busy signal is interrupted with a promotional message, con-
tact your central office to have it removed.
Setting F - Pulse Dialing Rate (Pulses per second)
The 1600A series phone is capable of different pulse dialing speeds.
*
The factory default setting is 10pps.
8
(memory location #18)
Dial: A + B + C + D + E + F + # + 1 + 8
The factory default is .2 seconds.
The factory default is 40 seconds.
This feature is disabled in the factory
The factory default is 3 minutes.
Touch Tone
1 or 0
2, 3, 4...9
Enter Timing/Dialing Settings Here:
A
B
C
D
E
F
Touch
Talk/Listen
Tone
1
2
3
4
5
6
7
8
9
Touch
Call Length
Tone
Time Out
0
Disabled
1
2
3
4
5
6
7
8
9
Touch
Tone
Time Out
0
Disabled
1
2
3
4
5
6
7
8
9
Setting D
Disabled*
Dials second number after
2, 3, 4...9 rings respectively
Touch Tone
Setting E
1
Disabled*
2
Enabled
Touch Tone
Setting F
1
10 pps*
2
20 pps
#18
Delay
.1 sec
.2 sec *
.3 sec
.4 sec
.5 sec
.6 sec
.7 sec
.8 sec
.9 sec
1 min
2 min
3 min*
4 min
5 min
6 min
7 min
8 min
9 min
Silence
10 sec
20 sec
30 sec
40 sec*
50 sec
60 sec
70 sec
80 sec
90 sec

Hide quick links: