Summary of Contents for Broadcast Tools DTD-16 + G2 NET
Page 1
NOTE: We recommend the use of Chrome, Firefox or Safari as your browser. Due to the dynamic nature of product design, the information contained in this document is subject to change without notice. Broadcast Tools, Inc., assumes no responsibility for errors and/or omissions contained in this document. Revisions of this information or new editions may be issued to incorporate such changes.
INTRODUCTION CAUTION! Thank you for your purchase of the DTD-16 + G2 NET DTMF Tone Decoder, which we will refer to throughout the manual as the DTD-16 + G2 NET. We are confident Broadcast Tools® this product will give you many years of dependable service. This manual is intend- Products, as with any ed to give you all the information needed to install and operate the Broadcast Tools®...
The package should contain the DTD-16 + G2 NET, a 9 VDC power supply, a USB-A/B cable, a “S9” RJ11-to-DB9 cable, a 7-foot BLUE straight-through CAT 5 cable, a 7-foot GRAY crossover CAT 5 cable.
NOTE: UPS Standby Power System We recommend that you connect your DTD-16 + G2 NET to a UPS standby power Never use any type of system. A UPS, like the BE600M1 from APC helps to minimize the risk to the DTD- power supply other 16 + G2 NET and provides power during a power outage.
USB PGM Port additional information. This type B USB port is used to connect the DTD-16 + G2 NET to a computer for configuration via a virtual COM port. See the “Programming” section of this manual for more information.
DTD-16+ G2 Net Installation and Operation Manual Relay Outputs The eight relay outputs are SPST normally open/dry. Make your connections to the desired relays K1 A/B through K8 A/B. Front panel LEDs indicate when a relay is active. Open Collector Outputs The open collector outputs are labeled OC9 through OC16.
DTD-16+ G2 Net Installation and Operation Manual Programming The DTD can be programmed from a computer via its USB serial, RS-232 serial, or Ethernet interface. See the “Ethernet” section of the manual for Ethernet setup instructions. Connecting via the USB Serial “PGM” port: 1.
DTD-16+ G2 Net Installation and Operation Manual Output Modes Momentary If you have selected the momentary function for this output channel, you can program two codes up to 5 digits for the first code and 6 digits for the second code that can be used to activate that output.
The default program values may be reloaded at any time by removing power from WEBSITE: the DTD-16 + G2 NET, holding down the PGM button and plugging in the power Visit our web site for and then releasing the PGM button after a few seconds. The PGM LED will blink product updates and once after the defaults are loaded.)
TOOLS®. DOING SO DELETES ALL SOFTWARE AND VOIDS ALL WAR- useful to contact your RANTIES FROM BROADCAST TOOLS, INC. IT department, network administrator or net- Instructions for changing the IP address of the computer that will be used for the work consultant for configuration of this product are given here.
Page 13
DTD-16+ G2 Net Installation and Operation Manual Step 2: Under Advanced Network Settings click Change adapter settings. The Network Connections windows will pop up, as shown below. Step 3: Right click on the icon labeled Local Area Connection or Ethernet. A menu will appear.
Page 14
DTD-16+ G2 Net Installation and Operation Manual Step 4: On the Local Area Connection Properties page, double click on Internet Protocol (TCP/IPv4) to display properties. Step 5: Before making any changes to the network settings, write down the current WEBSITE: settings (or screen capture the page and print) so that they can be restored Visit our web site for once the unit is configured.
DTD-16+ G2 Net Installation and Operation Manual 5. Click okay to connect to the DTD and type “p” into the terminal window and press return to enter programming mode. See: “Programming Steps” section of this manual. Changing network settings on the Ethernet “LAN/NET” port: WEBSITE: NOTE: We recommend the use of Chrome, Firefox, or Safari for as your browser.
Page 17
DTD-16+ G2 Net Installation and Operation Manual 5. To change the network settings, choose “Local IP Config” from the side bar: 6. The default work mode is TCP Server, TCP Client, UDP Server and UDP Client are also available. To change the TCP port choose “Serial Port” from the side bar and change the “Local Port Number”...
If Broadcast Tools is notified, in writing, of a failure of any item manufactured by Broadcast Tools to conform to the foregoing Limited Warranty within one (1) year following the date of the Buyer’s acquisition of the item, and if the item is returned to Broadcast Tools in accordance with Broadcast Tools’...
Page 21
Product_Name Installation and Operation Manual DTD-16 + G2 Net Component Layo T T o o ne Power RS-232 Audio Open Collector Relay Outputs 9-12VDC Port Serial Input Outputs 9-16 K1-K8 DTMF Tone Detection Jumper F = 50ms/50ms M = 100ms/100ms (default) S = 150ms/150ms JP1 –...
Need help?
Do you have a question about the DTD-16 + G2 NET and is the answer not in the manual?
Questions and answers