  • Page 1 PORTABLE GENERATOR Owner’s Manual GXS5000 DO NOT RETURN TO STORE! CALL US FIRST 855-888-3598 FOR SUPPORT Model# 2232006 REV00 Model: Serial: Date Purchased: SAVE THIS MANUAL FOR FUTURE REFERENCE P/N: 32082-05687-00...
  • Page 2: Table Of Contents

    Table of Contents Introduction..........1 Do Not Overload Generator....19 Maintenance And Storage....20 Safety............1 Maintenance Schedule......20 General Safety Precautions....2 Engine Maintenance......20 Unpacking the Generator.......7 Engine Oil Level Check......20 Parts Included........7 Change Engine Oil.......21 Assembly..........7 Spark Plug Maintenance......21 Install the Wheel Kit........7 Air Filter Maintenance......22 Install the Support Leg......8 Battery Cable Connection......8 Cleaning the Spark Arrestor....22...
  • Page 3: Introduction

    INTRODUCTION Read This Manual Thoroughly The information in this manual is accurate based on products produced at the time of publication. The WARNING manufacturer reserves the right to make technical updates, corrections and product revisions at any Read and understand manual completely time without notice.
  • Page 4: General Safety Precautions

    Asphyxiation Electric Shock Fire Hazard Hazard Hazard Hot Surface. Explosion Moving Parts Do Not Touch the Surface. Hazard Hazard Burn Hazard Operator’s Manual Kickback GENERAL SAFETY PRECAUTIONS • Operate this product ONLY outside far away from windows, doors and vents to reduce the risk of Using a generator indoors CAN KILL YOU IN MINUTES.
  • Page 5 CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: •...
  • Page 6 WHEN STARTING EQUIPMENT WARNING • Ensure spark plug, muffler, fuel cap, and air Starter cord kickback (rapid retraction) cleaner are in place. will pull hand and arm toward engine • DO NOT crank engine with spark plug removed. faster than you can let go which could WHEN OPERATING EQUIPMENT cause broken bones, fractures, bruises, or sprains resulting in serious injury.
  • Page 7 • It is a violation of California Public Resource Code, DANGER Section 4442, to use or operate the engine on any Contact with terminals, bare wires and forest-covered, brush-covered, or grass-covered electrical connections when generator land unless the exhaust system is equipped with a is running will result in death or serious spark arrester, as defined in Section 4442, injury.
  • Page 8 • DO NOT tamper with governor spring, links or other WARNING parts to increase engine speed. Generator supplies Medical and Life Support Uses. correct rated frequency and voltage when running • In case of emergency, call 911 immediately. at governed speed. •...
  • Page 9: Unpacking The Generator

    UNPACKING THE GENERATOR • Open carton completly. Remove and verify carton content prior to assembly. Your generator ships with following items. • Call our customer service at 855-888-3598 with the unit model and serial number for any missing item. • Record model, serial number, and date of purchase on front cover of this munual for your own record.
  • Page 10: Install The Support Leg

    4 - Secure everything with cotter pin (F), then assemble Cap(A) to Wheel(C). Repeat on opposite side. Install the Support Leg 5 - Insert bolts (G) throught the support leg (H) and 3-4mm holes on the generator frame as shown. 6 - Tighten bolts (G) and nuts (I) to the frame.
  • Page 11 Refer to the following instructions and pictures to Removal of Shipping Support Brackets remove the attached engine support brackets Before you can run your new generator, follow (red)(D) under the engine. these simple instructions: 1. Before filling the engine oil, tip the generator back The following items must be removed before running onto its recoil frame end as indicated in this your new generator.
  • Page 12: Controls And Features

    CONTROLS AND FEATURES 1 - Air Filter 8 - Recoil Starter 2 - Frame 9 - Engine 3 - Fuel Cap 10 - Starting Dial Switch 4 - Control Panel 11 - Support Leg 5 - Alternator Cover 12 - Muffler/Spark Arrester 6 - Fuel Tank 13 - Spark Plug 7 - Fuel Gauge...
  • Page 13: Control Panel Features

    CONTROL PANEL FEATURES 1. Data Center: Push the SELECT button to 6. Grounding Terminal: To ground the generator. display the voltage (V), frequency (Hz) and total 7. Low Oil Indicator: The Light will be illuminated run time(Hour). when the engine oil level is low. Add oil. 2.
  • Page 14: Specifications

    SPECIFICATIONS GXS5000 Model 2232006 Starting Watts 5000W Running Watts 4000W Rated AC Voltage 120V Rated DC Voltage Rated Frequency 60HZ Phase Single Grounding System (AC) Neutral Floating Engine Type Single Cylinder, 4-Stroke OHV Air Cooled Engine Displacement 223cc Starting System...
  • Page 15: Co Watch-Guard

    CO WATCH-GUARD Détection de monoxyde de carbone (CO) et système d'arrêt automatique Votre groupe électrogène est équipé du système de détection de monoxyde de carbone (CO) WATCH-GUARD pour votre protection et votre sécurité. Ce système de détection et d'arrêt surveille l'accumulation de gaz CO toxique autour du générateur, produit par l'échappement du moteur lorsque le générateur est en marche.
  • Page 16 Le générateur s'arrête automatiquement et le voyant jaune clignote pendant au moins cinq minutes après l'arrêt. Appelez le service clientèle A-iPower au 855-888-3598 pour une réparation. N'utilisez pas le générateur tant que le capteur ne fonctionne pas correctement. Le CO WATCH-GUARD ne doit être réparé...
  • Page 17: Add Engine Oil

    Add Engine Oil NOTICE We recommend using SAE 10W-30 APISJ oil for We consider the first 5 hours of run time to be the best performance. Other high-quality detergent oils break-in period for the unit. During the break in (APISJ or higher) are acceptable. Do not use special period stay at or below 50% of the running watt additives.
  • Page 18: Operation At High Altitude

    To operate at high altitudes A-iPower • If fuel spills, wait until it evaporates before starting can provide a high altitude carburetor main jet. The engine.
  • Page 19: Operation

    OPERATION Generator Location Starting the Generator 1. Make certain the generator is on a flat, level surface WARNING and well-ventilated location. Check for loose or Make sure you review each warning in order to missing parts and for any damage which may have prevent fire hazard.
  • Page 20: Connecting Electrical Loads

    NOTE: When applying a load, do not exceed the 6. Start maximum wattage rating of the generator when using Move the choke lever to one or more receptacles. Also, do not exceed the the “START” position. amperage rating of any one receptacle. Do not apply heavy electrical load during break-in period (the first five hours of operations).
  • Page 21: Low Oil Shutdown

    WARNING Fuel and its vapors are extremely flammable and explosive which could cause burns, fire or explosion resulting in death or serious injury. DO NOT stop engine by moving choke control to “START” position. NOTE: Always ensure that the fuel valve is in the “OFF” position when the engine is not in use.
  • Page 22: Maintenance And Storage

    MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE NOTE: Maintenance should be performed more frequently Regular Maintenance will improve the performance when generator is used in dusty areas. and extend the life of your generator. Follow When generator has exceeded the maximum figures maintenance schedule intervals whichever occurs specified in the table, maintenance should still be first according to use.
  • Page 23: Change Engine Oil

    Recommended Engine Oil Type CAUTION 10W-30 Avoid prolonged or repeated skin contact with used motor oil. 5W-30 10W-40 1. Remove the oil cap (A) and wipe dipstick clean. 5W-30 Full Synthetic 2. Place a container underneath the oil drain plug to °F collect used lubricant as it drains.
  • Page 24: Air Filter Maintenance

    7. Tighten with wrench to compress washer. If spark Cleaning the Spark Arrestor plug is new, use 1/2 turn to compress washer 1. Allow the engine to cool completely before appropriate amount. If reusing old spark plug, use servicing the spark arrestor. 1/8 to 1/4 turn for proper washer compression.
  • Page 25: Generator Maintenance

    GENERATOR MAINTENANCE 6 - Pull starter recoil several times to distribute oil in cylinder. Make certain that the generator is kept clean and 7 - Install spark plug. stored properly. Only operate the unit on a flat, level 8 - Pull recoil slowly until resistance is felt. This surface in a clean, dry operating environment.
  • Page 26: Trouble Shooting

    TROUBLE SHOOTING PROBLEM Engine is running, 1. AC Circuit breaker is open. 1. Check AC load and reset circuit breaker. but no AC output is 2. Fault in generator. 2. Contact customer service or authorized service center. available. 3. Poor connection or defective cord set. 3.
  • Page 27: Parts Diagram And Parts List

    PARTS DIAGRAM AND PARTS LIST GXS5000 PARTS DIAGRAM Page 25...
  • Page 28: Parts List

    Parts List Part Number Description Qty. Part Number Description Qty. 30101-00070-00 Hex flange bolt M6*12 30101-00487-00 Hex flange bolt M10*15 20021-00009-00 Cylinder cover components 30136-00078-00 Aluminum gasket 34024-00003-00 Clamp 34011-00105-00 Crankcase 34023-00016-00 Exhaust hose 34007-00003-00 Oil seal 33048-00024-00 Cylinder head gasket 33015-00037-00 Oil hose protection sleeve 34021-00012-00...
  • Page 29 Part Number Description Qty. Part Number Description Qty. 30101-00410-00 Hex flange bolt M6*28 33593-00018-00 Carbon canister pressure plate A 30101-00041-00 Hex flange bolt M6*10 33593-00024-00 Carbon canister pressure plate B 33138-00015-00 Dust shield 34030-00015-00 Vibration damping support A 20029-13616-00 Generator assy. 34030-00020-00 Vibration damping support B 30101-00086-00...
  • Page 30: Circuit Diagram

    Circuit Diagram Page 28...
  • Page 31: Warranty

    Warranty Term ups resulting from improper maintenance. A-iPower will provide warranty for any of its products Additional exclusions - this warranty does not cover purchased through any authorized AiPower dealer in wearable parts such as filers, spark plugs, o-rings, North America to the original purchaser and will be batteries etc.
  • Page 32 Warranty limits and Implications and Consequential Damages A-iPower is not obligated to cover any loss of time, use of product, freight cost, or any other incidental or consequential claim from the use of this product. This warranty is in Lieu of all other warranties, express or implied.
  • Page 33 Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.com...
  • Page 34 Features Product Appearance Warranty Ease of Maintenance Noise Level 5 . HOW LIKELY ARE YOU TO RECOMMEND A-iPOWER TO FAMILY OR FRIENDS? Extremely Not Likely Likely at all Privacy Statement: A-ipower is committed to respecting your privacy and to complying with the regulations regarding the protection of personal data.
  • Page 35 Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.com...

This manual is also suitable for:

2232006

Table of Contents