ELEGANCE “16” Low Carbon Fan with EC Motor Installation and Operating Instructions • SAP PCDB Listed • 3 speed continuous running • 6 models: - standard - delay-on timer - humidity control - SELV - low voltage • for all domestic wet rooms •...
Page 2
Elegance “16” - HIGH PERFORMANCE, LOW CARBON FANS INSTALLATION and OPERATING INSTRUCTIONS THIS LEAFLET MUST BE AVAILABLE TO THE USER The product you have purchased is an extrac- check that the product will still operate cor- tor fan for exhausting directly outside or rectly.
Page 3
for the product to be installed. chemical and corrosive agents, flammable or • The electrical supply to which the fan is con- explosive mixtures. nected must comply with all existing regula- • The product must be installed by profes tions. All installations must comply with cur= sionally qualified personnel.
Page 4
RANGE Trickle Speed 1 - 8 l/sec - 28.8 m EL1003HDT - 3 speed, continuous running fan. ³ Trickle Speed 2 - 16 l/sec - 57.6 m The fan runs continuously at the pre-selected ³/ lower speed, and the boost (speed 2) will start EL1003 - this fan combines the latest technol- to operate automatically when the relative ogy with energy saving and efficiency.
Page 7
INSTALLATION IMPORTANT check there is nothing missing in box If the fan is installed in a ceiling with a vertical exploded diagram duct passing through an unheated space, a drill hole in wall - allow extra width if condensation trap MUST be fitted. Any duct- using ducting - it is the installer's ing in an unheated space should also be insu- responsibility to use the appropriate...
JUMPER SWITCH These fans are designed to run continuously at one of 2 lower speeds fixed at installa- tion using the jumper switch. Fig 13: - EL1003, EL1003DT and EL1003HDT (and SELV models) Minimum Speed 1 - Jumper 1 Minimum Speed 2 - Jumper 2 Fig 14: to activate delay-on timer in EL1003DT and EL1003HDT...
TRIMMER ADJUSTMENT To adjust the humidistat and timer trim- mers, remove the front cover of the fan (Fig 2) to access the trimmers. The humidistat (HY) can be adjusted between 40% and 90% relative humidity. Turn clockwise to decrease sensitivity and set at a higher level of relative humidity.
WIRING DIAGRAMS ELs - 3 Speed with Cor ELs - 3 Speed via remote switch When installing fans via a remote switch, pullcord switch must be put in the "off" position and the cord removed. ELs - SELV - 3 Speed with Cord ELs - SELV - 3 Speed via remote switch SELV All SELV (safety extra low voltage) products...
CLEANING and MAINTENANCE Before any cleaning or maintenance operation, the fan should be switched off and disconnected from the main power supply. The front cover can be cleaned by the user with a dry cloth or soft brush. If any maintenance is required, this should be done by a professional technician.