Page 1
ELEGANCE EL1203 Low Carbon Fan with EC Motor Installation and Operating Instructions • 3 models: ⁻ 3 speed continuous running ⁻ timer ⁻ humidity control • for all domestic wet rooms • for walls or ceilings IPX4...
Page 2
” - HIGH PERFORMANCE, LOW CARBON FANS “Elegance INSTALLATION and OPERATING INSTRUCTIONS THIS LEAFLET MUST BE AVAILABLE TO THE USER The product you have purchased is an extractor fan • do not touch it with wet or damp parts of the for exhausting directly outside or through medium body (eg hands, feet).
Page 3
WARNING: Damage could be caused to the product if RANGE Trickle Speed 1 - 13 lt/sec - 47 m³/h the installation instructions are not followed Trickle Speed 2 - 19 lt/sec - 68 m³/h • The product should not be used in an ambient tem- perature higher than 40°C (104°F).
Page 6
INSTALLATION 1. check there is nothing missing in box. 2. remove front cover. 3. drill hole in wall - allow extra width if using ducting - it is the installer’s responsibility to use the appropriate core cutter to obtain the correct hole diameter. 4.
JUMPER SWITCH These fans are designed to run continuously at one of 2 lower speeds fixed at installation using the jumper switch. EL1203, EL1203DT and EL1203HDT (fig 11) Minimum Speed 1 - Jumper 1 Minimum Speed 2 - Jumper 2 To activate delay-on timer in EL1203DT and EL1203HDT plug Jumper on position 3 (fig 12)
This product has been designed and constructed using high-quality materials and components that can be recycled or re-used. Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire, HP12 3RH Tel: +44 (0)1494 522333. Fax: +44 (0)1494 522337. Email: sales@vectaire.co.uk Web: www.vectaire.co.uk...