Data load [Data import]
1
Connect a USB memory device to the controller's USB port.
• The files to be imported must be stored in the folder "DMX Move Control 512"located on the root
directory of the USB memory device.
2
Call the menu item with the pan wheel and confirm with ENTER.
• The display indicates "Press number key Select file" (select file with number button).
• The control LED of a number button lights, when data is available on the USB memory device for this
memory bank.
3
Select the file to be loaded with the number buttons 1-16.
• The display indicates a progress bar.
4
After successful completion of the data import, the device returns to the main menu level.
Black-out mode [Blackout function]
It is possible to define whether all control channels react on the button BLACK OUT or only the dimmer control
channel.
1
Call the menu item with the pan wheel and confirm with ENTER.
2
Use the pan wheel to choose between the settings [All channels] and [Only dimmer].
• All channels: All control channels react on the button (i.e. in the blackout state the control channels
have the value zero).
• Only dimmer: Only the dimmer control channel reacts on the button BLACK OUT
(i.e. in the blackout state the control channel has the value zero).
3
Confirm your setting with ENTER.
• The display shortly indicates "SAVE OK" and returns to the main menu level.

5. CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts. Should you have further questions, please
contact your dealer.

6. TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
Number of control channels:
Storable scenes:
Storable chases:
Sound control:
DMX512/RDM output:
Available storage media:
Dimensions (LxWxH):
Weight:
Please note: Every information is subject to change without prior notice. 14.02.2014 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
100-240 V AC, 50/60 Hz ~ via included power unit
2.7 W
512
32
32 with 100 steps each
via built-in microphone
3-pin XLR connector
USB devices (FAT32)
483 x 130 x 82 mm Rack installation with 3 U
2.2 kg