Specifications - Kenwood CS-5135 Instruction Manual

4omhz dual trace readout oscilloscope
Hide thumbs Also See for CS-5135:
Table of Contents

Advertisement

SPECIFICATIONS
CS-5130
CS-5135
CRT
150 mm rectangular with internal graticule
Acceleration Voltage
~ 12 kV
Display Area
8x10 div (1 div=10 mm)
VERTICAL AXIS (CH1 and CH2)
Sensitivity
1 mV/div to 5 V/div:
1 mV to 2 mV/div
+5%,
5 mV/div to 5 V/div +3%
Attenuator
12 steps, 1 mV/div to 5 V/div in 1-2-5 sequence
Vernier control for fully adjustable sensitivity between steps
Input Impedance
1 MQ +2%, approx. 30 pF
Frequency
|
Response
DC to 40 MHz, within
—3 dB (5 mV/div to 5 V/div)
DC to 15 MHz, within
—3 dB (1 mV/div to 2 mV/div)
5 Hz to 40 MHz, within
—3 dB (5 mV/div to 5 V/div)
5 Hz to 15 MHz, within
—3 dB (1 mV/div to 2 mV/div)
Rise Time
8.7 ns (5 mV/div to 5 V/div)
17.5 ns (1 mV/div & 2 mV/div)
Signal Delay Time
Adequate to identify leading edge
Crosstalk
—40 dB or less (at 1 kHz)
Operating Modes
Single trace
Single trace
Two-waveform
display, alternately
Chop Frequency
Channel Polarity
/\ Maximum Input Voltage
HORIZONTAL
AXIS Input thru
Operating Modes
Two-waveform
display, chopped
CH1+(+CH2)
added display
Approx. 300 kHz
Normal or inverted, channel 2 only inverted
500 Vp-p or 250 V (DC +AC peak)
CH2, x10 MAG not included
X-Y operation is selectable with HORIZ MODE switch
CH1: Y axis
CH2 : X axis
Sensitivity
Same as vertical axis (CH2)
Input Impedance
Same as vertical axis (CH2)
Frequency
| DC
DC to.1 MHz, within —3 dB
Response
| AC
5 Hz to 1 MHz, within —3 dB
X-Y Phase Difference
3° or less at 100 kHz
A Maximum Input Voltage
Same as vertical axis (CH2)
SWEEP
Type
A
A sweep
A sweep (intensified for duration of B sweep) and B sweep (delayed sweep) alternating
B
Delayed sweep
x-Y
X-Y oscilloscope operation
Sweep Time
A
0.2 ps/div to 0.5 s/div +3%, in 20 ranges, in 1-2-5 sequence
Vernier control for fully adjustable sweep time between steps
B
0.2 ps/div to 50 ms/div +3%, in 17 ranges, in 1-2-5 sequence
Sweep Magnification
X10 (ten times) +5%
(+8% in 0.2 ys-to-0.5 ws range)
Linearity
+3%
(+5% for x10 magnification)
Holdoff
Continuously variable from NORM to more than ten time (MAX)
Trace Separation
Delayed Sweep
Continuous delay (AFTER DELAY) & triggered delay (B TRIG' D: triggered by A trigger)
Delay Time
Continuous adjustable from 0.2 us/div to 0.5 s/div

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-5130