Sony BVE-600 Maintenance Manual page 10

Editing control unit
Table of Contents

Advertisement

vi) S308 MIXER CONTROL SWITCH :
REMOTE
: MXP-29 is controlled.
LOCAL
: MXP-29 is not used.
When the unit is shipped, it is set to REMOTE.
S309 CF-REF VTR SW: VTR locks by itself, according to the lock-range of each VTR Player.
$310 Player 1 VTR, CF PHASE SW:
It compensates the phase of the color framel, player 1.
S311 PLAYER 2 VTR, CF PHASE SWITCH:
It compensates the phase of the color frame, player 2.
«i
S312 RECORDER VTR CF LEARN SWITCH:
When the recorder has the CF LOCK function and the $312 is pushed, BVE-600 follows the information detected by the
recorder VTR.
«i) S313 STATUS DISPLAY SWITCH:
ON
: STATUS is displayed on the monitor.
OFF : STATUS
is not displayed on the monitor.
When the unit is shipped, it is set to ON.
) SW-232 Board
i) S601 NORMAL/REVERSE
SWITCH : It switches over NORMAL
or REVERSE of the wipe patterns.
)
)
CN-249 Board:
S501 : 75Q TERMINATION SWITCH FOR REF VIDEO SIGNAL
ON : The bridge is connected.
OFF : The bridge is not connected.
When the unit is shipped, it's set to ON.
Gels
1
6 7 8 OFF
When the unit is shipped, $502's bits 1 thru 8 are all set to ON.
Gi) S503 :
AGGGGGGE
123
4 5 6 7 8 OFF
When the unit is shipped, it is set to EXT.
(iv) S4 REF VIDEO SIGNAL SELECT SWITCH:
EXT:
Optional boards (BKE series) are inserted to the unit.
INT:
Optional boards (BKE series) are not inserted to the unit.
When the unit is shipped, $503's bits 1 thru 8 are all set to ON.
(6) DP-77 (P1)/(P2)/(R) Boards
(i)
Sl
;RESET
When the time counter display switch is set to "CTL" and S1 is pushed, CTL is reset. At this time, display becomes
0:00 : 00: 00.
1-6