Technical Data - Bentone BENTOFLEX ST 120 KAV Installation And Maintenance Instruction

Table of Contents

Advertisement

TECHNICAL DATA

ST 120 KAV
Dimensions
B
194
Burner tube
Length of burner
tube
KAV
147
KAV
224
Output range and nozzles recommended
Burner tube
Oil capacity
kg/h
KAV
2,0-5,6
The net caloriic value of 11,86 kWh/kg for light oil has been used.
Recommended nozzle
Because of different boiler types
existing on the market, with varying
combustion chamber designs, it is
Electrode adjustment
2,7-3,3
8,0-9,0
148
Incl. lange A
Measure B
109
186
Capacity
kW
Mcal/h
24-66
20-57
not possible to state a deinite spray
angle or spray pattern.
0,5-1,5
275
Incl. lange B
Measure B
122
199
Recommended
Nozzle
Angle
60°, 80°
Incl. lange C
Incl. lange D
Measure B
Measure B
130
207
Recommended Pump
pressure
Type
Bar
H, S
10
Note that the spray angle and the
spray pattern change with the pump
pressure.
171 225 24 08-01
129
206

Advertisement

Table of Contents
loading

Table of Contents