Bühler technologies Precooler TS 10 Installation And Operation Instruction Manual

Advertisement

Quick Links

Gas Analysis
Precooler
TS 10
Installation and Operation Instructions
Original instructions
BE450009
Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen
10/2018
Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20
E-Mail: analyse@buehler-technologies.com
Internet: www.buehler-technologies.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Precooler TS 10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bühler technologies Precooler TS 10

  • Page 1 Gas Analysis Precooler TS 10 Installation and Operation Instructions Original instructions BE450009 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen 10/2018 Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 E-Mail: analyse@buehler-technologies.com Internet: www.buehler-technologies.com...
  • Page 2 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 Internet: www.buehler-technologies.com E-Mail: analyse@buehler-technologies.com Read this instruction carefully prior to installation and/or use. Pay at- tention particularly to all advises and safety instructions to prevent in- juries.
  • Page 3: Table Of Contents

    TS 10 Contents Introduction .............................................  2 Intended use .........................................  2 Types............................................ 2 Scope of delivery ........................................ 2 Safety instructions .........................................  3 Important advice .........................................  3 General hazard warnings .................................... 4 Transport and storage ........................................ 5 4 Installation and connection ...................................... 6 Installation site requirements.................................. 6 Installation .......................................... 6 4.2.1 Peristaltic pump .................................... 6...
  • Page 4: Introduction

    TS 10 1 Introduction 1.1 Intended use This unit is intended for industrial use in gas analysis systems. It's an essential component for conditioning the sample gas to protect the analysis instrument from residual moisture in the sample gas. Please note the specifications in the data sheet on the specific intended use, existing material combinations, as well as pressure and temperature limits.
  • Page 5: Safety Instructions

    TS 10 2 Safety instructions 2.1 Important advice Operation of the device is only valid if: – the product is used under the conditions described in the installation- and operation instruction, the intended application according to the type plate and the intended use. In case of unauthorized modifications done by the user Bühler Technolo- gies GmbH can not be held responsible for any damage, –...
  • Page 6: General Hazard Warnings

    TS 10 2.2 General hazard warnings The equipment must be installed by a professional familiar with the safety requirements and risks. Be sure to observe the safety regulations and generally applicable rules of technology relevant for the installation site. Prevent malfunctions and avoid personal injuries and property damage.
  • Page 7: Transport And Storage

    TS 10 3 Transport and storage Only transport the product inside the original packaging or a suitable alternative. The equipment must be protected from moisture and heat when not in use. It must be stored in a covered, dry and dust-free room at a temperature of -20 °C to 60 °C (-4 °F to 140 °F).
  • Page 8: Installation And Connection

    TS 10 4 Installation and connection 4.1 Installation site requirements The unit is only intended for wall-mounted use in enclosed areas. Adequate protection from the weather must be provided when used outdoors. Install the unit leaving enough room below the cooler to discharge the condensate. Leave room above for the gas supply. Be sure to maintain the approved ambient temperature.
  • Page 9 TS 10 CAUTION Wrong mains voltage Wrong mains voltage may damage the device. Regard the correct mains voltage as given on the type plate. Plug connection This device has one DIN 43650 plug each for the power supply. If the lead is connected correctly, these cannot be confused. Therefore please be sure to correctly reassemble the plugs after connecting the wires.
  • Page 10: Operation And Control

    TS 10 5 Operation and control NOTICE The device must not be operated beyond its specifications. After switching on the cooler, both the pump and fan will start. Please refer to the data sheet or technical data for performance data and maximum ratings. Bühler Technologies GmbH BE450009 ◦...
  • Page 11: Maintenance

    TS 10 6 Maintenance The basic version of the cooler requires no special maintenance. However, it may have different options depending on the cooler model. In this case the following maintenance must be per- formed regularly: – Optional peristaltic pump: Check hoses During maintenance, remember: –...
  • Page 12: Service And Repair

    TS 10 7 Service and repair This chapter contains information on troubleshooting and correction should an error occur during operation. Repairs to the unit must be performed by Bühler authorised personnel. Please contact our Service Department with any questions: Tel.: +49-(0)2102-498955 or your agent If the equipment is not functioning properly after correcting any malfunctions and switching on the power, it must be inspected by the manufacturer.
  • Page 13: Replacing The Hoses Of The Peristaltic Pump (Option)

    TS 10 7.3 Replacing the hoses of the peristaltic pump (option) – Turn off gas supply. – Switch the device off and disconnect power supply. – Remove the supplying and draining hoses from the pump (Take care of the safety instructions!). –...
  • Page 14: Disposal

    TS 10 8 Disposal The applicable national laws must be observed when disposing of the products. Disposal must not result in a danger to health and environment. The crossed out wheelie bin symbol on Bühler Technologies GmbH electrical and electronic products indicates special disposal notices within the European Union (EU).
  • Page 15: Appendices

    TS 10 9 Appendices 9.1 Technical Data TS 10 precooler Technical Data Ambient temperature: 0 .. 60 °C Electric supply: 115 V, 60 Hz or 230 V, 50 Hz Power input: 25 W Type of protection electric: IP 20 Housing: Stainless steel Installation: wall-mounted...
  • Page 16: Attached Documents

    TS 10 10 Attached documents – KX450008 Declaration of Conformity – RMA - Decontamination Statement Bühler Technologies GmbH BE450009 ◦ 10/2018...
  • Page 19 RMA-Formular und Erklärung über Dekontaminierung RMA-Form and explanation for decontamination RMA-Nr./ RMA-No. Die RMA-Nr. bekommen Sie von Ihrem Ansprechpartner im Vertrieb oder Service. Bei Rücksendung eines Altgeräts zur Entsorgung tragen Sie bitte in das Feld der RMA-Nr. "WEEE" ein./ You may obtain the RMA number from your sales or ser- vice representative.