Table of Contents

Advertisement

MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
FUZE REPLACEMENT
Locate and remove the unit's power cord. Once the cord has been removed, locat the fuse holder inside
the power socket. Insert a flat-head screw driver into the power socket, and gently pry out the fuse
holder. Remove the bad fuse, and replace with a new one. The fuse holder has a built-in socket for a
spare fuse be sure not to confuse the spare fuse with active fuse.
CLEANING
Frequent cleaning is recommended to ensure proper function, optimized light output, and an extended
life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky,
or particularly dirty environments can cause greater accumulation of dirt on the fixture's optics. Clean
the external lens surface periodically with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.

MAINTENANCE

Regular inspections are recommended to ensure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service issues to an
authorized ADJ service technician. Should you need any spare parts, please order genuine parts from
your local ADJ dealer.
Please refer to the following points during routine inspections:
-
A detailed electrical check by an approved electrical engineer every three months, to make sure the
circuit contacts are in good condition in order to prevent overheating.
-
Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out
during normal operation, resulting in damage or injury as larger parts could fall.
-
Check for any deformations on the housing, color lenses, rigging hardware, and rigging points
(ceiling, suspension, trussing). Deformations in the housing could allow for dust or liquids to enter
into the fixture. Damaged rigging points or unsecured rigging could cause fixture to fall and seriously
injure a person(s).
-
Electric power supply cables must not show any damage, material fatigue, or sediments.
NEVER remove the ground prong from the power cable.
-
32

Advertisement

Table of Contents
loading

Table of Contents