5-22. Input Capacity (Option 03 Only).
A2R38
A2C28
A2R3l
A2R17
400CPS
ADJUST
1omMC
ADJUST
BIAS
ADJUST
BIAS
ADJUST
DC OUTPUT
ATTENUATOR
ADJUST
ADJUST
ADJUST
(ADJUST
FROM SIDE)
(ADJUST
FROM
BOTTOM)
Figure 5-3.
Location of Internal Adjustments
5-26. COVER REMOVAL.
5-28. To remove a side cover,
remove the four Phillips screws and lift if off
5-29. BIAS ADJUST.
5-30. Connect a de voltmeter (410C) to TP3 and adjust A2R17 for -6.0 +0. 25 val.
Connect a de voltmeter to TP4 and adjust A2R31 for +10.0 +0. 5 vdc.