STOPPING THE GENERATOR:

8.4.
Turn the "Fuel Saving" switch to the "Off" position.
8.4.1.
Turn off the power switch of the electric equipment and unplug the cord
8.4.2.
from the receptacle of the generator.
Turn the "Combined" switch to the "Stop" position.
8.4.3.
Allow the engine to cool down for about three minutes with no load prior to
switching it off.
8.4.4.
After the generator has cooled down, turn the "Air Knob" on top of the
"Fuel Cap" to the "Off" position.
8.4.5.
For recoil starter models turn the switch to the "OFF" position
8.4.6.
For electric start models, press the button to stop the engine and turn off
the battery switch.

OIL SENSOR:

8.5.
The oil sensor detects a drop in the oil level in the crank case and
8.5.1.
automatically stops the engine when oil level drops below a
predetermined level.
8.5.2.
When engine has stops automatically switch off the generator's
circuit breaker and check the oil level. Refill with engine oil to the
upper level as instructed on clause 6.1, and then restart the
engine.
8.5.3.
If the engine does not start, please recheck the oil level.
CAUTION
Do not remove the OIL SENSOR PROBE when refilling
with oil. Remove the oil filler cap on the opposite side of
carburetor.
13