Radio Shack PRO-2035 Service Manual page 15

Programmable scanner
Hide thumbs Also See for PRO-2035:
Table of Contents

Advertisement

(
48.5 MHz and 10.7 MHz WFM IF CoU Alignment
Control Setting
Test Instrument Connection
Adjust
Result
OFFNOLUME control: ON.
Conneet the signal generator to
T3
1. Set the signal generator fre-
SQUELCH
control:
CCW.
the ANT jack, and the
osclllo-
T4
quency to 520 MHz (FM: 22.5
Select channel 5.
scope, AC SSVM, distortion
kHz dey. at 1 kHz and the
meter, and 8-ohm load to the
output at SIN 20 dB point).
EXT SPKR jack. See Figure 5.
2. Adjust T3 and T4 lor maxi-
mum sensitivity.
48.5 MHz 2nd IF CoU Alignment
Control Setting
Test Instrument Connection
Adjust
Result
OFFNOLUME
control:
ON.
Conneet the signal generator to
T2
1.
Set the signal generator Ire-
SQUELCH control: CCW.
the ANT jack, and the oscillo-
T6
quency to 120 MHz (AM: 60%
Select channel 6.
scope, AC SSVM, distortion
modo at 1 kHz and the output
meter, and 8-ohm load to the
at SIN 20 dB point).
EXT SPKR jack. See Figure 5.
2. Adjust T2 and T6 lor maximum
sensitivity.
455 kHz IF Coil Alignment
Control Setting
Test Instrument Connection
Adjust
Result
OFFNOLUME control: ON.
Conneet the signal generator to
T7
1.
Set the signal generator
tre-
SQUELCH control: CCW.
the ANT jack, and the oscillo-
quency to 120 MHz (AM: 60%
Select channel 6.
scope,
AC SSVM, distortion
modo at 1 kHz and the output
meter, and 8-ohm load to the
at SIN 20 dB point).
EXT SPKR jack. See Figure 5.
2. Adjust T7 lor maximum sensi-
tivity.
455 kHz AM Detector Coil Alignment
Control Setting
Test Instrument Connection
Adjust
Result
OFFNOLUME control: ON.
Conneet the signal generator to
T8
1. Set the signal generator Ire-
SQUELCH
control.
CCW.
the ANT jack, and the oscillo-
quency to 120 MHz (AM: 60%
Select channel 6.
scope,
AC SSVM, distortion
modo at 400 Hz and the out-
meter, and 8-ohm load to the
put at 100 I-lV).
EXT SPKR jack. See Figure 5.
2. Adjust T8 lor minimum THD
point.
-15-