8
Preparing for Installation
IMPOR
IMPORT T T T T ANT
IMPOR
IMPOR
IMPOR
Plan the installation so that the electrical connection, gas shut-off valve, and
pressure regulator are accessible from the front of the cabinet and so that all of the
E36GC76EPS: 42" (1067mm) Recommended
Figure 1
E36GC76EPS: 36" (914mm) Minimum
E48GC76EPS: 54" (1372mm) Recommended
E48GC76EPS: 48" (1219mm) Minimum
10" (254mm)
5/8" (16mm) Overhang, both sides
Min. to
combustible side
wall, both sides
E36GC76EPS: 36" (914mm)
E48GC76EPS: 48" (1219mm)
(152mm)
ANT
ANT
ANT
ANT
When installing the cooktop into a laminated (Formica, etc.) or synthetic (Corian,
etc.) countertop, radius the corners of the cutout to prevent cracking of the
countertop.
Follow the countertop manufacturer's instructions regarding the minimum corner
radius, use of heat reflective tape, reinforcement of corners, etc.
If cabinet storage space is to be provided directly above the cooktop, the risk of
personal injury may be reduced by installing a ventilating hood that projects
horizontally a minimum of 5 inches beyond the face of the cabinets.
Both models are designed to allow installation in standard 24 inch deep base
cabinets with 25 inch overall depth countertops. Deeper cabinets and
countertops may be used to provide required clearances to combustible rear wall
materials or for design purposes.
The specified cabinet dimensions must be provided. The cabinet and/or
countertop must completely enclose the recessed portion of the countertop.
All contact surfaces between the appliance and the countertop must be solid
and level.
36" (914mm) Minimum
48" (1219mm) Minimum
Hood
1 1/2" (38mm)
Typical Countertop
Cooktop opening
Utilities
Location
E36GC76EPS:
6"
24" (610mm)
E48GC76EPS: 30" (762mm)
C
L
minimum required
dimensions are provided.
Dimensions apply to both
models unless otherwise
stated (see Figure 1). Locate
the electrical supply box
within reach of the included
48 inch long flexible cord so
the connection is accessible
when the cooktop is in place.
30" (762mm)
Minimum
18"
(457mm)
7 3/4"
(197mm)
36"
(914mm)
15 1/2"
28 1/4"
(393mm)
(717mm)
10"
(254mm)

Advertisement