Hide thumbs Also See for 89df Series:

Advertisement

Quick Links

89 Dual Media Tank
Water Filter Manual
1. This manual contains important safety and operating instructions. Read all instructions and follow
them when using this product. Failure to consider this information and follow these instructions,
including those concerning maintenance, may result in property damage, injury and or death.
Page 23 of this manual contains important maintenance procedures for the continued proper
operation of your unit. These MUST be performed regularly for your warranty to remain valid.
2. We recommend installation only be completed by a competent installer or plumbing professional to insure this
product is installed in accordance with local plumbing codes.
3. Read this manual in full and follow all instructions carefully before operation.
4. Avoid pinched O-rings during installation by applying NSF certified lubricant to all seals (provided with install kit).
5. This system is not intended for treating water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
6. Discard small parts remaining after the installation.
7. Failure to install the system correctly voids the warranty.
8. Handle all components of the system with care. Do not drop, drag or turn components upside down.
9. Save these instructions and keep track of your product's serial number.
NOTICE: THIS MANUAL CONTAINS A LIMITED WARRANTY. BY INSTALLING AND OR USING THIS PRODUCT, YOU WAIVE
CERTAIN LEGAL RIGHTS INCLUDING THE RIGHT TO SUE OR CLAIM COMPENSATION IN THE EVENT OF PROPERTY
DAMAGE, INJURY, AND OR DEATH.
Canature WaterGroup Canada Inc.
855 Park St., Unit 1
Regina, SK, S4N 6M1
Toll Free: (877) 288-9888
IAPMO R & T Certified
Against NSF/ANSI 42
Canature WaterGroup U.S.A. Inc.
6353 Commerce Drive
Whitestown, IN, 46075
Toll Free: (877) 288-9888

Advertisement

Table of Contents
loading

Summary of Contents for Canature WaterGroup 89df Series

  • Page 1 NOTICE: THIS MANUAL CONTAINS A LIMITED WARRANTY. BY INSTALLING AND OR USING THIS PRODUCT, YOU WAIVE CERTAIN LEGAL RIGHTS INCLUDING THE RIGHT TO SUE OR CLAIM COMPENSATION IN THE EVENT OF PROPERTY DAMAGE, INJURY, AND OR DEATH. Canature WaterGroup Canada Inc. Canature WaterGroup U.S.A. Inc. 855 Park St., Unit 1...
  • Page 2: Table Of Contents

    SAFETY FIND AND RECORD VALVE TYPE & SERIAL NUMBERS RECORDS & CONTACTS KNOW THIS BEFORE STARTING YOUR INSTALLATION HOW YOUR WATER FILTER WORKS FEATURES & TERMINOLOGY FLOW RATE INFORMATION FEED WATER PARAMETERS BACKWASHING INSTRUCTIONS UNPACKING/INSPECTION BEFORE INSTALLATION PREPARATIONS PLANNING YOUR INSTALLATION INSTALLATION STEPS UNDERSTAND THE SCREEN &...
  • Page 3: Safety

    Used to depict a specific behavior that MUST be followed to avoid the present hazard (problem). Canature WaterGroup U.S.A. Inc. / Canature WaterGroup Canada Inc. (“Canature”) has disclosed all known risks associated with the product within this manual but cannot disclose risks that are beyond its knowledge.
  • Page 4: Find And Record Valve Type & Serial Numbers

    FIND AND RECORD VALVE TYPE & SERIAL NUMBERS There are two labels located on your Unit: 1) Control valve label and 2) System number label. Find and record your product model number, serial number, and valve serial number in the Records & Contacts section as they will be important if you need to troubleshoot. Item # Model # Control Valve Serial #...
  • Page 5: Know This Before Starting Your Installation

    KNOW THIS BEFORE STARTING YOUR INSTALLATION   Read this manual thoroughly to become familiar with Do not use this filter on hot water supply lines. the filter and its capabilities before installing or  Avoid pinched O-rings during installation by applying the operating.
  • Page 6 KNOW THIS BEFORE STARTING YOUR INSTALLATION (CONTINUED) The BIF, BIFMN, BAF and BIFHS all have individual design parameters that must be followed. Please review and verify correct sizing for your application utilizing the chart supplied below and by using the following formula: (Iron mg/l ________ X 1) + (manganese mg/l ________ X 2) + (Hydrogen Sulphide mg/l _______X 3) = Total Iron mg/l ________ BIF, BIFMN, BAF, and BIFCC Sizing and Application Guide Chart size is as follows:...
  • Page 7: How Your Water Filter Works

    HOW YOUR WATER FILTER WORKS The BIF/BAF systems work by adding oxygen to the incoming water by passing it through a bubble of compressed air. The water is then passed through a special filter bed. The special media not only increases the pH of the water to enhance iron removal but also acts as a physical barrier to trap iron precipitate. As more water passes through this iron filter, the oxygen in the unit is used up, and the media gets loaded with iron.
  • Page 8: Feed Water Parameters

    FEED WATER PARAMETERS ALL UNITS BIFMN BIFCC (Catalytic Carbon) Maximum Iron = 30 ppm ferrous or ferric Maximum Iron = 0.0 ppm ferrous or ferric Maximum TDS = 2000 ppm Maximum Sulphates = 500 ppm Maximum Manganese = 1.0 ppm Maximum Manganese = 0.0 ppm Maximum Hardness = 75 gpg Maximum Hydrogen Sulfide = 3.0 ppm...
  • Page 9: Backwashing Instructions

    BACKWASHING INSTRUCTIONS The BIF, BIFMN, BAF and BIFHS all have individual design parameters that must be followed. Instructions for Chart Use From your water test results add the following together: Iron ppm plus manganese mg/l x 2 plus Hydrogen sulfide ppm x 3. EG 1ppm plus .5 x 2 = 1.0 plus .5 x 3= 1.5 will give you a compensated iron amount of 3.5 locate 3.5 (round up) on the chart if assuming it fits into the area that is shaded with a Y in it then the unit is sized correctly.
  • Page 10: Unpacking/Inspection

    UNPACKING/INSPECTION Be sure to check the entire unit for any shipping damage or parts loss. Also note damage to the shipping cartons. Contact the transportation company for all damage and loss claims. The manufacturer is not responsible for damages in transit. Small parts, needed to install the filter, are in a parts box.
  • Page 11: Before Installation

    BEFORE INSTALLATION Make sure you have a copy of your most recent water test results. If your water has not been tested previously, your professional installer can obtain a water sample bottle to be sent to one of our facilities for a free analysis. It is important that this product not be installed until you have this information.
  • Page 12: Preparations

    PREPARATIONS 3. Fill the gravel support bed first. A large funnel makes filling the MEDIA INSTALLATION tank much easier. Order part #99003 Follow the steps below for proper media loading. separately for your own funnel. Slowly add the gravel. Depending on the type of system, add the resin, or 2.
  • Page 13 PREPARATIONS BIFMM Models Multi Media Sand Filter Support Bed (when supplied) Gravel 4. Apply the supplied lubricant (part #92360) to the internal O-ring at the bottom of the control valve. Apply lubricant to the larger O-ring on the bottom of the valve that seals with the tank threads. Internal O-ring NOTICE Do NOT use petroleum-based...
  • Page 14: Planning Your Installation

    PLANNING YOUR INSTALLATION WATER FILTER INSTALLATION LAYOUT Select the location for your filter tank with care. Various conditions that contribute to proper location include: 1. All installation procedures must conform to local or regional plumbing codes. Canature is not liable for any non-compliance with local requirements 2.
  • Page 15 PLANNING YOUR INSTALLATION (CONTINUED) WATER FILTER INSTALLATION NOTE Check valve needs to be installed on Drain Elbow the inlet side of the system. Assembly AC120V/10A Current Protect Socket Outlet Inlet 5/8” Overflow Line Main tank Floor drain Optional Pipes Fixed Structure Laundry Drain NOTE...
  • Page 16: Installation Steps

    INSTALLATION STEPS TO BEGIN YOUR INSTALLATION: 1. Make sure the bypass is attached securely to the control valve. 2. Apply thread tape to threaded connections elbow plumbing adaptors 3. Apply the supplied lubricant (#92360) to the O-rings of the fittings. 4.
  • Page 17 INSTALLATION STEPS (CONTINUED) 7. Using the included Allen key, place the unit in the bypass position. a. Slowly turn the main water supply ON. b. At the nearest cold treated water tap, remove the tap screen, OPEN the tap and let water run a few minutes or until the system is free of any air or foreign material resulting from the plumbing work.
  • Page 18: Understand The Screen & Keypad Configuration

    UNDERSTAND THE SCREEN & KEYPAD CONFIGURATION The control valve is controlled with simple, user-friendly electronics, displayed on an LCD screen Connect the Transformer Connect the transformer to the unit by plugging the 12 volt transformer into a 120 VAC 60 Hz outlet MANDATORY Do NOT use an outlet that is controlled by a light switch.
  • Page 19: Start-Up Instructions

    START-UP INSTRUCTIONS Now that your water conditioner is plumbed into position it is time to start up and program the unit. STEP 1. PURGE AIR FROM THE UNIT Backwash Flow Rate : 00.00GPM Key Locked, 25-DEC-2025 06:30AM Any Key 3S to Next Press Key for 5S Remain:001234GAL...
  • Page 20 START-UP INSTRUCTIONS (CONTINUED) STEP 3. HOW TO SET DATE AND TIME, MANUAL REGENERATION, DEALER INFO Key Locked, Press Key for 5S to Unlock Press and hold button one (1), the display will read “PRESS 5 Seconds to Unlock”. After 5 seconds, the display will beep confirming unlock. Press button one (1) to enter user programming.
  • Page 21 OTHER MAIN MENU FEATURES To Initiate a Manual Regeneration Regen Now? Date and Time Hardness Regen Tonight? Manual Regen. Dealer Information Press [ ] To Cancel Salt Reminder Press [ ] To Confirm! Main Menu Press buttons two (2) or four (4) to select Regen Press buttons two (2) or four (4) to select Now or Regen Tonight.
  • Page 22: Plumbing System Clean Up

    PLUMBING SYSTEM CLEAN UP The following procedures are guidelines only but have proven successful in most instances. Under no circumstances should any procedure outlined below be followed if contrary to any other household appliances manufacturer’s instruction(s). Should there be any questions concerning the advisability of performing a procedure, it is strongly recommended that the dealer be consulted prior to performing the procedure.
  • Page 23: System Maintenance

    SYSTEM MAINTENANCE Maintenance of your new water filter requires very little time or effort but is essential. Regular maintenance will ensure many years of efficient and trouble-free operation. Check with your local dealer about setting up a regular maintenance plan.Failure to follow maintenance instructions and schedule will result in the unit failing to operate properly and void your warranty.
  • Page 24 SERVICING YOUR CONTROL VALVE (CONTINUED) INSPECTION & REPLACEMENT OF PISTON ASSEMBLY AND SEAL & SPACER KIT Remove all Piston Seal and Screws Assembly Spacer Brine Valve Assembly 1. Follow steps 1 to 3 of Powerhead Removal 3. Remove the plate from the valve body and 5.
  • Page 25: Troubleshooting Guide

    TROUBLESHOOTING GUIDE NOTE Before attempting any troubleshooting, be sure to test the water. The tests should include; 1. Raw water 2. Hot treated water 3. Cold treated water. Problem Cause Correction 1. Filter bleeds taste and odor or A. Bypass valve is open A.
  • Page 26: Common Spare Parts

    COMMON SPARE PARTS Part Number Description 60090026 Elbow, Inlet/Outlet, 1” NPT Comes with O-Ring 60090027 Straight, Inlet/Outlet, 1” NPT Comes with O-ring 60090040 Elbow, Drain line, 1/2” NPT Comes with O-Ring 60090029 Elbow, Drain line, 3/4” NPT Comes with O-Ring 60090030 Elbow, Drain line, 1”...
  • Page 28: Warranty

    Warranty on Control Valve and Parts: Canature WaterGroup™ will replace or repair any part (except for Wear and Tear Items – Media, Piston, Seals and Brine Valve) which fails within seven (7) years from date of manufacture, as indicated by the serial number, provided the failure is due to a defect in material or workmanship. The only exception from the date of manufacture shall be proof of purchase or installation is provided and then the warranty period shall be from the date thereof.

Table of Contents