Generac Power Systems PowerBOSS 5500 Owner's Manual

Generac Power Systems PowerBOSS 5500 Owner's Manual

Powerboss 5500 watt storm-plus portable generator
Hide thumbs Also See for PowerBOSS 5500:
Table of Contents

Advertisement

Available languages

Available languages

Portable Generator Owner's Manual
Questions? Help is just a moment away!
Call: Generac Generator Helpline - 1-800-270-1408 M-F 8-5 CT
Web: www.generac-portables.com or www.briggsandstratton.com
Model No. 1642-2 (5,500 Watt AC Generator) Manual No. 189439GS Revision 1 (10/15/2002)

Advertisement

Table of Contents
loading

Summary of Contents for Generac Power Systems PowerBOSS 5500

  • Page 1 Portable Generator Owner’s Manual Questions? Help is just a moment away! Call: Generac Generator Helpline - 1-800-270-1408 M-F 8-5 CT Web: www.generac-portables.com or www.briggsandstratton.com Model No. 1642-2 (5,500 Watt AC Generator) Manual No. 189439GS Revision 1 (10/15/2002)
  • Page 2: Equipment Description

    PowerBoss 5,500 Watt Storm-Plus Generator EQUIPMENT DANGER DESCRIPTION Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, Read this manual carefully and become fainting or death. familiar with your pressure washer. Know its applications, its limitations and any hazards •...
  • Page 3 PowerBoss 5,500 Watt Storm-Plus Generator WARNING WARNING Gasoline and its vapors are extremely flammable Running engines produce heat.Temperature of and explosive. muffler and nearby areas can reach or exceed 150°F (65°C). Fire or explosion can cause severe burns or death. Severe burns can occur on contact.
  • Page 4: Know Your Generator

    PowerBoss 5,500 Watt Storm-Plus Generator KNOW YOUR GENERATOR Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Fuel Tank Spark Arrester Muffler Choke Lever...
  • Page 5: Install Wheel Kit

    PowerBoss 5,500 Watt Storm-Plus Generator ASSEMBLY Install Wheel Kit IMPORTANT:This wheel kit is not intended for Your generator requires some assembly and is ready for over-the-road use. use after it has been properly serviced with the recommended oil and fuel. To install your wheel kit you need the following tools: If you have any problems with the assembly of your •...
  • Page 6: Before Starting The Engine

    PowerBoss 5,500 Watt Storm-Plus Generator Repeat step 3 through 5 to secure second wheel. Add Gasoline Remove the temporary blocks. WARNING! NEVER fill fuel tank indoors. NEVER To aid support leg assembly, rest generator on cradle, fill fuel tank when engine is running or hot. Allow engine end down.
  • Page 7: Grounding The Generator

    PowerBoss 5,500 Watt Storm-Plus Generator GROUNDING THE OPERATING THE GENERATOR GENERATOR The National Electrical Code requires that the frame and CAUTION! NEVER start or stop the engine external electrically conductive parts of this generator be with electrical loads connected to the receptacles properly connected to an approved earth ground.
  • Page 8: Connecting Electrical Loads

    PowerBoss 5,500 Watt Storm-Plus Generator Set the rocker switch to “On” position (Figure 6). RECEPTACLES Figure 6 — Rocker Switch 120/240 Volt AC, 30 Amp, Locking Receptacle Use a NEMA L14–30 plug with this receptacle. Connect a 4–wire cord set rated for 250 Volt AC loads at 30 Amps (or greater) (Figure 7).You can use the same 4–wire cord if you Grasp the recoil handle and pull slowly until slight plan to run a 120 Volt load.
  • Page 9: Cold Weather Operation

    PowerBoss 5,500 Watt Storm-Plus Generator 120 Volt AC, 20 Amp, Duplex COLD WEATHER Receptacles OPERATION Each duplex receptacle (Figure 8) is protected against overload by a push–to–reset circuit breaker. Under certain weather conditions (temperatures below 40°F [4°C] and a high dew point), your generator may Figure 8 —...
  • Page 10: Power Management

    PowerBoss 5,500 Watt Storm-Plus Generator DON'T OVERLOAD YOUR Plug in and turn on the next load. Again, permit the generator to stabilize. GENERATOR Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, Capacity as described above.
  • Page 11: Specifications

    PowerBoss 5,500 Watt Storm-Plus Generator SPECIFICATIONS Generator Maintenance Generator maintenance consists of keeping the unit clean Maximum Surge Watts ....8,500 watts and dry. Operate and store the unit in a clean dry Continuous Wattage Capacity .
  • Page 12: Generator Storage

    PowerBoss 5,500 Watt Storm-Plus Generator STORAGE Engine Storage See engine owner’s manual for instructions. The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot Other Storage Tips be done and you must store the unit for more than •...
  • Page 13: Troubleshooting

    PowerBoss 5,500 Watt Storm-Plus Generator TROUBLESHOOTING Problem Cause Solution Circuit breaker is open. Reset circuit breaker. Poor connection or defective cord set. Check and repair. Engine is running, but Connected device is bad. Connect another device that is in good no AC output is condition.
  • Page 14 PowerBoss 5,500 Watt Storm-Plus Generator SCHEMATIC...
  • Page 15: Wiring Diagram

    PowerBoss 5,500 Watt Storm-Plus Generator WIRING DIAGRAM...
  • Page 16: Exploded View - Main Unit

    PowerBoss 5,500 Watt Storm-Plus Generator EXPLODED VIEW – MAIN UNIT...
  • Page 17 PowerBoss 5,500 Watt Storm-Plus Generator PARTS LIST – MAIN UNIT Item Part # Qty Description Item Part # Qty Description B189444GS 1 CRADLE 45 189235GS 1 DECAL, Start Instructions 70642GS 4 MOUNT,Vibration 46 22097GS 4 WASHER, Lock 76222GS 3 SCREW 47 22127GS 4 NUT 190220GS...
  • Page 18 PowerBoss 5,500 Watt Storm-Plus Generator EXPLODED VIEW AND PARTS LIST – WHEEL KIT Item Part # Qty Description 189715GS 1 ASSY, Handle B1764GS 1 LEG, Mounting 52858GS 4 NUT, Lock 39287GS 2 SCREW 191267HGS 1 AXLE B4966GS 2 WHEEL 191265GS 2 E-RING 22247GS 2 WASHER...
  • Page 19 PowerBoss 5,500 Watt Storm-Plus Generator EXPLODED VIEW AND PARTS LIST – CONTROL PANEL Item Part # Qty Description 188914GS 1 COVER, Lid, Control Panel 188889GS 1 CONTROL PANEL, Compact 189167GS 2 CLIP, Pin Retainer 189182GS 2 SPRING, Hinge 189166GS 2 PIN, Hinge 68759GS 2 OUTLET, 120 V, 20 A 189165GS...
  • Page 20 PowerBoss 5,500 Watt Storm-Plus Generator EXPLODED VIEW AND PARTS LIST – ALTERNATOR Item Part # Qty Description 186059GS 1 ADAPTER, Mount 190032GS 1 ASSY, ROTOR 190079AGS 1 ASSY, STATOR 186060GS 1 RBC, with O-Ring (p/n 189197GS) 86308HGS 4 SCREW 91825GS 1 ASSY, Holder, Rectifier/Brush 66849GS 2 SCREW...
  • Page 21 PowerBoss 5,500 Watt Storm-Plus Generator NOTES...
  • Page 22: Descripción Del Equipo

    PowerBoss 5,500 Watt Storm-Plus Generador DESCRIPCIÓN DEL EQUIPO PELIGRO Al generador funcionar, se produce monóxido de Lea este manual de manera cuidadosa y familiarícese con su generador. Conozca sus usos, carbono, un gas inodoro y venenoso. sus limitaciones y cualquier peligro relacionado El respirar el monóxido de carbono, producirá...
  • Page 23 PowerBoss 5,500 Watt Storm-Plus Generador ADVERTENCIA ADVERTENCIA Los motores al funcionar producen calor. La La gasolina y sus vapores son extremadamente temperatura del silenciador y de las áreas cercanas inflamables y explosivos. puede alcanzar o pasar los 150°F (65°C). El fuego o una explosión pueden causar quemaduras Quemaduras severas pueden ocurrir al hacer contacto.
  • Page 24: Conozca Su Generador

    PowerBoss 5,500 Watt Storm-Plus Generador CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIO Y LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR. Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras.
  • Page 25: Montaje

    PowerBoss 5,500 Watt Storm-Plus Generador MONTAJE Instale el Juego de Ruedas IMPORTANTE: Este Juego de Ruedas no ha sido diseñado para Su generador requiere de ciertos procedimientos de montaje y ser usado en la carretera. solo estará listo para ser utilizado después de haberle suministrado servicio con el combustible y aceite recomendados.
  • Page 26: Agregar Aceite Al Motor

    PowerBoss 5,500 Watt Storm-Plus Generador Repita los pasos 3 por 5 para asegurar la segunda rueda. ¡ADVERTENCIA! NO llene excesivamente el tanque de combustible. Deje suficiente espacio para la expansión Remueva los bloques temporales. del combustible. Para ayudar al ensamblaje de la pata de apoyo, haga descansar el generador en la camilla con la parte del motor •...
  • Page 27: Encienda El Motor

    PowerBoss 5,500 Watt Storm-Plus Generador CONEXION A TIERRA DEL OPERANDO EL GENERADOR GENERADOR ¡PRECAUCIÓN! NUNCA encienda o pare el motor El Código Nacional de Electricidad exige que el marco y las con las cargas eléctricas conectadas a los receptáculos Y partes exteriores del generador conductoras de electricidad, con los aparatos conectados ENCENDIDOS.
  • Page 28: Parado Del Motor

    PowerBoss 5,500 Watt Storm-Plus Generador Coloque el interruptor balancín a la posición "On" RECEPTÁCULOS (Figura 16). Figura 16 — Interruptor Balancín 120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Use un tapón NEMA L14-30 con este receptáculo. Conecte un juego de cable de 4 alambres, clasificado como 250 Voltios AC a 30 Amps (o mayor) (Figura 17).
  • Page 29: Operación Durante Un Clima Frío

    PowerBoss 5,500 Watt Storm-Plus Generador 120 Volt AC, 20 Amp, Receptáculos Dobles Operación Durante un Clima Frío Cada receptáculo (Figura 18) está protegido en contra de Bajo ciertas condiciones ambientales (temperaturas por debajo de sobrecargas por un corto-circuitos de, del tipo "empuje para los 40ºF [4ºC] y un punto alto Dew), su generador puede reposicionar".
  • Page 30: No Sobrecargue El Generador

    PowerBoss 5,500 Watt Storm-Plus Generador NO SOBRECARGUE EL Conecte y encienda la próxima carga. De nuevo, permita que el generador se estabilice. GENERADOR Repita los pasos 4 y 5 para cada carga adicional que usted tenga. Capacidad NUNCA añada más cargas sobre la capacidad del generador.Tome Usted debe asegurarse que su generador puede proveer el una atención especial en considerar las cargas de corriente según suficiente vataje calificado (cuando esté...
  • Page 31: Especificaciones

    PowerBoss 5,500 Watt Storm-Plus Generador ESPECIFICACIONES Mantenimiento del Generador El mantenimiento del generador consiste en conservar la unidad Potencia Máxima ..... 8,500 Vatios (8.5 kW) limpia y seca.
  • Page 32 PowerBoss 5,500 Watt Storm-Plus Generador ALMACENAMIENTO Almacenando el Motor Consulte el manual del propietario del motor para las El generador deberá ser encendido al menos una vez cada siete instrucciones de cómo preparar adecuadamente el motor para su días y deberá dejarlo funcionar al menos durante 30 minutos. Si almacenamiento.
  • Page 33 PowerBoss 5,500 Watt Storm-Plus Generador NOTAS...
  • Page 34: Diagnositicos De Averías

    PowerBoss 5,500 Watt Storm-Plus Generador DIAGNOSITICOS DE AVERÍAS Problemo Causa Accion El interruptor automático de circuito está Reposicione el interruptor. abierto. El motor está Conexión mal o defectuosa del juego de Revise y repare. funcionando pero no cables. existe salida de AC El dispositivo conectado está...
  • Page 35: Garantía Limitada

    Usted puede ubicar su Concesionario de Servicio Autorizado de los Productos Portátiles de Generac más cercano, en nuestro mapa localizador de concesionarios en www.generac-portables.com o llame al 1-877-544-0982. Los Productos Portátiles de Generac están fabricados bajo una o más de las siguientes patentes: (Otras patentes están pendientes) 5902094 5823752 5718255 5890413 Generac Portable Products, LLC Jefferson,Wisconsin U.S.A.
  • Page 36: Limited Warranty

    LIMITED WARRANTY "Generac Portable Products, LLC will repair or replace, free of charge, any part, or parts of the equipment that are defective in material or workmanship or both.Transportation charges on parts submitted for repair or replacement under this Warranty must be borne by purchaser.

This manual is also suitable for:

Powerboss 5500 storm-plus

Table of Contents