5
MX'er 50
. FUEL SYSTEM
Remove the two carburetor lock nuts.
Remove the carburetor.
Nuts

AUTO BYSTARTER

AUTO BYSTARTER INSPECTION
Measure the resistance between the auto
bystarter wire terminals.
Resistance:
5W (10 minutes minimum
after
stopping the engine)
If the resistance exceeds 5W, replace the auto
bystarter with a new one.
After the engine stops for 30 minutes,
connect a hose to the fuel enriching circuit
and blow the hose with mouth.
If air cannot be blown into the hose
(clogged), the auto bystarter is faulty.
Replace it with a new one.