6.4 Transmission of clear text
1.
2.
Release all buttons and
push LINE button
lamp lights up, paper is illuminated,
line warning lamp lights.
Actuate shunt device — text input is printed/punched and
e v e r y 4 s e c o n d s w h i l s t t r a n s m i t t e d . B l o c k e d k e y b o a r d /
using keyboard or tape reader tape reader indicate necessity of
actuating shunt device again.
Push OUT button
- AROFLEX returns to standby
mode.
Transmission of "Here Is"
— upon receipt of a "Who Are You ? "
signal, the "Here Is" signal is
transmitted.
6.5 Transmission of classified text 1. Push OFF-LINE button
2. Push INDIRECT button
3. Push PROC button
Type required compartment
address
Type Station Identification
and CR.
Type clear-text heading as
required. For ACP-127
compliance, use PREAMBLE
for Format Lines 5 ... 11
— lamp lights up, paper is illuminated
— PROC and INDIRECT lamps
light up.
— AROFLEX prints serial no. and
checkword of indicator key Z
(if present), followed by SELECT.
— AROFLEX prints address cha-
acter, serial no. and checkword
of key, followed by PAGE 1 on
new line.
— AROFLEX generates 15 LFs.
RESTRICTED