RESTRICTED
2 9
If correct key is not present,
AROFLEX responds as shown
in next column. Set required
key and repeat deciphering
procedure.
Procedure signal sounds.
CORR lamp flashes slowly.
AROFLEX prints serial number of
required key (if indicator key is
present in compartment Z).
If cryptogram contains format Procedure signal sounds,
errors, AROFLEX responds as CORR lamp lit continuously,
shown in next column. Use Tape reader blocked.
CORR button as described in
paragraph 4.7 See also Note (4).
When cryptogram has been
entered completely, switch
on tape punch (15) and push
OUTPUT button (10)
Lamp lights in OUTPUT button.
AROFLEX generates 15 x LF,
pauses for a few seconds, then
prints/punches deciphered text, end
ing with serial number and check-
word of key used.
NOTES
(1) The lamp in the OUTPUT button remains lit until the con
tents of the memory have been completely printed/punched.
(2) The lamp in the INDIRECT button remains lit until the
memory is cleared.
(3) The output can be repeated as many times as required; it
can also be stopped at any point (by pressing the lit OUTPUT
button) and re-started at the beginning (by pressing the lit
OUTPUT button again).
(4) Interim printout (e.g. to check the effect of corrections)
can be obtained by pressing the OUTPUT button at any
time during input. Input can be resumed when printing stops.
RESTRICTED