SleepSense Operation
LOGIC ( SleepSense)
At first, unit will operate cooling mode for 60 minutes at setting condition.
With the motion sensor, the room air conditioner can monitor human movement. If no human movement is
detected, then the temperature will increase by 1℃( in case of cooling operation ) automatically and The fan
speed will be changed to silent fan speed.
Unit continues running for another 1 hour.
If the condition of activity in the room is stable then the unit will continue running with the temperature
increased by another 1°C( in case of cooling) respectively.
During the SleepSense operation , if Big activity /movement is detected, the temperature and Fan speed will
resume back to previous setting.
During the SleepSense operation , if small activity /movement is detected, the temperature will decreased
by 1℃.
AQtiv-Ion
By pressing
(AQtiv-Ion) button during Heat, Auto, Cool, Dry,
Fan operation, the AQtiv-Ion operation start.
To Start AQtiv-Ion operation
1
Press the AQtiv-Ion button
To Cancel AQtiv-Ion operation
2
Press the
On/Off button.
Press the AQtiv-Ion button
will be disappear on LCD.
- 24 -
.
is display on LCD screen.
again.