Do you have a question about the SP-18 and is the answer not in the manual?
Questions and answers
Robert Peavler
February 18, 2025
water not going in tray. does get cold
1 comments:
Mr. Anderson
February 18, 2025
The document does not provide a direct answer to why water is not going into the tray of the U-Line SP-18, even though it gets cold. However, potential causes may include a blocked or disconnected water supply line, a faulty water valve, or an issue with the unit's internal components. Checking the water line connection and ensuring proper installation may help resolve the issue.
General Precautions Use this appliance for its intended purpose only and follow these general precautions along with those listed throughout this guide: WARNING SHOCK HAZARD — Electrical Grounding Required. • Keep the unit unplugged throughout installation except during testing. • Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
Door Swing/Clearances Information Units have a zero clearance for the door to open 90° (see Figure 3). U-Line recommends a minimum door clearance of 3/4" to accommodate the flange if the unit is right-hand hinged and installed next to a wall or similar type of structure.
Reversing the Door All units may be left- or right-hand opening. To reverse the door: 1. Remove travel pin from cabinet (two screws). See Figure 4. Slide assembly through flange and set aside to be used later. 2. Remove top hinge from cabinet (three screws).
Figure 12 Figure 11 9. Gently slide upper hinge through flange and fasten upper hinge to unit (three screws). Partially tighten screws. See Figure 11. 10. Place door on lower hinge pin. 11. Align door pivot hole with pivot hole in upper hinge and insert pivot screw into upper hinge and tighten securely.
(see Figure 17). However, make certain that the tubing is not pinched or damaged during installation. • U-Line recommends the use of copper tubing for installation. To connect to water supply: 1. Install the 1/4 inch OD copper water line from the main water source.
Figure 15 Figure 16 2. Locate the compression fitting and ferrule packed with the unit. Slide the compression fitting and ferrule over the 1/4-inch OD water supply line. Do not use thread sealing compound or tape. Using two wrenches, tighten the compression fitting on the supply line (see Figure 15).
7 Level the Unit Leveling Information IMPORTANT It is extremely important that the unit sits on a level surface, as it does not have feet levelers. If it is not level, the ice mold will not fill evenly. Use a level to check the levelness of the unit from front to back and from side...
9 Start-Up for the First Time Initial Start-Up The on/off switch is located on the front grille. Ensure that the switch is turned on. No setting adjustments should be necessary at this time. For information about Adjusting the Temperature Control, see the User Manual. As soon as the ice maker mold reaches the proper temperature, the ice maker...
For more than four decades, U-Line has distinguished itself as the leader in built-in undercounter ice making, refrigeration and wine storage appliances. U-Line Corporation, located in Milwaukee, WI, is a family operated manufacturer of built-in undercounter icemakers, Combo ®...
Need help?
Do you have a question about the SP-18 and is the answer not in the manual?
Questions and answers
water not going in tray. does get cold
The document does not provide a direct answer to why water is not going into the tray of the U-Line SP-18, even though it gets cold. However, potential causes may include a blocked or disconnected water supply line, a faulty water valve, or an issue with the unit's internal components. Checking the water line connection and ensuring proper installation may help resolve the issue.
This answer is automatically generated