MODEL NUMBER: H8000
HUMIDIFYING MODE: Cool/Warm Ultrasonic Mist
POWER SUPPLY: 120V, 60Hz
POWER CONSUMPTION: 30W (Cool Mist); 130W (Warm Mist)
TANK CAPACITY: 2.0 gallons
SUCCESSIVE HUMIDITY HOURS: Up to 120 hours depending on environmental conditions
DIMENSIONS: 7.25"L x 9.76"W x 13.98"H
WEIGHT: 6.0 pounds
POWER
Turns humidifier ON/OFF.
COOL/WARM MIST & NIGHT LIGHT CONTROL
Select humidifying temperature based on need. Warm humidity will use more power but will humidify your room quicker. Turns night light on/off.
AUTO HUMIDISTAT
Monitors the humidity in the room and adjusts output to maintain an ideal humidity of 50%.
TIMER
Preset the humidifier to automatically turn off in 1 to 12 hours.
ADJUSTABLE HUMIDISTAT
Preset the humidifier to run at necessary time and mist control setting to reach desired humidity.
MIST CONTROL
The spray volume or amount of mist that is produced by the unit can be adjusted to three levels based on need.
SILVER CLEAN TECHNOLOGY
Unlike other humidifiers that grow slimy mold and mildew, the pureguardian Ultrasonic Humidifier uses Silver Clean technology embedded in the tank to fight the growth of mildew and mold on the surface of the water tank.
Select a firm, level, flat location - at least six inches (15 cm) from any wall or object for proper air flow. Place the humidifier on a water-resistant surface, as water can damage furniture and some flooring. Do not place unit directly on carpet, towels, blankets or other absorbent surfaces.
Guardian Technologies will not accept responsibility for damage caused by water spillage.
Make sure unit is unplugged.
Turns night light on/off. Selects cool or warm mist. Water temperature is maintained at room temperature for cool setting and 80 degrees for warm. Allow 15 minutes for water to warm.
Follow instructions for desired combination. The images show the screen display for the combination of the cool/warm mist and night light settings.
= Warm
= Night Light
Default: Night light/Warm mist control on.
Press 1 time: Night light OFF. Warm mist ON.
Press 2 times: Night light ON. Cool mist ON.
Press 3 times: Night light OFF. Cool mist ON.
Press the Auto button to activate the automatic humidity function, then the ideal humidity of 50% is maintained. When the humidity level in the room is less than the auto humidity level (50%), the humidifier will continue to produce moisture automatically. Once the room level is met, the humidifier will turn itself off.
Press the Timer button to determine the operating time, it can be regulated between 1 and 12 hours or for continuous operation.
Set the desired humidity in % by pressing the Adjustable Humidistat button. We recommend a relative humidity of between 40% and 50%. The appliance can be regulated from 40% to 75% in 5% increments. If the humidity exceeds the desired setting, the appliance will turn itself off. The appliance will not turn itself off if it has been set for Continuous Operation ("Co"). The desired value is shown while you are making the selection. After a few seconds, the display automatically switches to the current value. Note: If the room humidity is below 15% then the display will flash.
When you press the Mist Control button there are three options:
Press once for LOW.
Press twice for MEDIUM.
Press three times for HIGH (no icons will be displayed for this combination).
When it is time to refill, the low water indicator will blink on the display.
If scale becomes difficult to remove with brush:
Are minerals in your water producing white dust?
Try Decalcification Cartridge FLTDC
Look for cartridge at your local retailer or visit
www.guardiantechnologies.com
NOTE: IF YOU EXpERIENCE A pRObLEM DO NOT ATTEMpT TO OpEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR pERSONAL INJURY.
PROBLEM | SOLUTION |
Water vapor and humidity are not produced. | Power Plug: Unplug and then try again. Power Failure: When the power is returned, try again. Tank Installation: Make sure the tank is correctly attached. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. |
Air blows but water vapor is not produced. | Excessive Water: Remove a certain amount of water from the tank. The desired humidity is lower than the current temperature: Increase the desired humidity. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. If you use hard water, replace with softer water. |
Humidity level is low. | The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. The water in the unit is too cold: Replace with cool, but not cold water. Damage on the ultrasonic disk: Contact Customer Service 1.866.603.5900 |
Warm humidity is not produced. | It may take 10-15 minutes before warm humidity is created. The mist may not feel warm due to the fact it is so fine and is cooled rather quickly from the air in your home. Test by either feeling the base of the unit which should be warm to the touch or by allowing the unit to run for approximately 30 minutes on warm setting in a closed 200 sq. foot room or smaller. The room should feel moderately warmer if the unit is working properly. |
The humidity has a bad smell. | Poor maintenance or dirty water: Clean the product thoroughly, and fill it with fresh water. |
White dust is forming on nearby furniture. | Hard water may deposit a certain amount of dust. Dust in the air also settles because of added humidity in the room. Use distilled water if this becomes a nuisance. * Decalcification Filter (FLTDC) available at www.guardiantechnologies.com or through Customer Service 1.866.603.5900. |
Unit has stopped working. | No or low water. Unplug unit and refill tank. |
Water is accumulating outside of unit or area surrounding unit. | Saturation of humidity. Lower mist control setting. Unit not level and water is accumulating. Unplug and place on level surface. Point spray away from objects. Raise unit on a water-resistant level surface 2-3 feet off of floor. |
Water dripping when refilling. Cap not tight. | Water remaining on bottom of tank. Wipe tank or tilt to drain before transporting. Twist to firmly secure cap after filling tank with water. |
Increased noise level. | Unit must be placed on a flat, level, hard surface. Make sure it is NOT placed on a soft or absorbent surface. |
Humidifier display not reaching "auto" or desired humidity level. | There are a few things that can affect the reading. Also, unplugging it for a period of 5-8 minutes. Sometimes it is possible to overload the unit when first getting the product and trying out all the buttons. |
Failure to comply with the warnings listed below may result in electric shock or serious injury.
This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
The cords, wires and/or cables supplied with this product contain chemicals, including lead or lead compounds, known to the state of California to cause cancer and birth defects or other reproductive harm. Wash hands after using.
(California code of regulations Proposition 65)
READ AND SAVE THESE INSTRUCTIONS
The product warranty registration can be completed online at www.guardiantechnologies.com. Address returns to the attention of: Customer Service, at the address below. Additional questions or comments can be made toll free to the number listed below.
Guardian Technologies LLC
26251 bluestone blvd.
Euclid, Ohio 44132
1.866.603.5900
www.guardiantechnologies.com
Guardian Technologies LLC
26251 Bluestone Blvd. | Euclid, Ohio 44132