Initial Starting Procedure; Normal Sweep Display Operation - Kenwood CS-1022 Instruction Manual

Hide thumbs Also See for CS-1022:
Table of Contents

Advertisement

OPERATION
INITIAL STARTING PROCEDURE
Until you familiarize yourself with the use of all controls,
the following procedure may be used to standarize the in-
itial setting of controls as a reference point and to obtain
5V/div
CAL
AC
CENTER
5V/div
CAL
AC
CENTER
(1) NORMAL SWEEP DISPLAY OPERATION
1. Turn the POWER
contro!
@
clockwise — the power
supply will be turned on and the pilot lamp will light.
Set these modes as follows;
MODE 42 :
CH1
TRIG MODE
@ : AUTO
. The trace will appear in the center of the CRT display
and can be adjusted by the CH1
+ POSITION
@ and
<>
POSITION
&) controls. Next, adjust the INTENSI-
TY
@ and, if necessary, the FOCUS
48 for ease of
observation.
. Vertical Modes
With vertical MODE
@
set to CH1, apply an input
signal to the CH1
INPUT
©) jack and
adjust the
VOLTS/DIV
@ control for a suitable size display of the
waveform.
If the
waveform
does
not
appear
in the
display, adjust the VOLTS/DIV and ¥ POSITION controls
to bring the waveform into the center portion of the CRT
display. Operation with a signal applied to the CH2 IN-
PUT
@
jack and the vertical MODE set to CH2 is
similar to the above procedure.
In the ADD
mode, the algebraic sum of CH1+CH2
is
displayed. If the CH2 INV 49 switch has been engag-
ed, the algebraic
difference
of the two
waveforms,
CH1 — CH2 is displayed. If both channels are set to the
same
VOLTS/DIV,
the sum
or difference can be read
directly in VOLTS/DIV from the CRT. In the ALT mode,
trace on the CRT in preparation for waveform observation.
When
using the probe(s), refer to probe's instructions and
""PROBE COMPENSATION"
listed in APPLICATION of this
manual.
CENTER, PUSH
1ms/div
CAL
AUTO
CS-1022, 1012
V. MODE
Ac.
C8-1020,1010
INT
CENTER, PUSH
CENTER
CENTER
Fig. 7
(1) NORMAL SWEEP DISPLAY OPERATION
1. Turn the POWER
control
(3 clockwise—the power
supply will be turned on and the pilot lamp will light. Set
the TRIG MODE
@) to AUTO position.
. The trace will appear in the center of the CRT display
and can be adjusted by the # POSITION
@ ard <>
POSITION
@
controls.
Next,
adjust the INTENSITY
and,
if necessary,
the FOCUS
'48
for ease
of
observation.
. Apply an input signal to INPUT
@) jack and adjust the
VOLTS/DIV
@ control for a suitable size display of the
waveform.
If the
waveform
does
not
appear
in the
display, adjust the VOLTS/DIV and * POSITION controls
to bring the waveform into the center portion of the CRT
display.
. If no trace is obtainable, refer to the following TRIGGER-
ING procedures.
The display on the screen will probably be unsynchroniz-
ed.
Refer to TRIGGERING
procedures below adjusting syn-
chronization and sweep speed to obtain a stable (jsplay
showing the desired number of waveforms.
TRIGGERING
The
input signal
must
be properly
triggered
for stable
waveform
observation.
TRIGGERING
is possible the input
signal INTernally to create a trigger or with an EXT» rnally

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-1021Cs-1012Cs-1020Cs-1010

Table of Contents