Checking The Relays - Yamaha YZ 2015 Series Owner's Service Manual

Table of Contents

Advertisement

d. Adjust the voltage so that the current is at
the standard charging level.
e. Set the time according to the charging time
suitable for the open-circuit voltage.
f. If charging requires more than 5 hours, it is
advisable to check the charging current after
a lapse of 5 hours. If there is any change in
the amperage, readjust the voltage to obtain
the standard charging current.
g. Measure the battery open-circuit voltage af-
ter leaving the battery unused for more than
30 minutes.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
Charging method using a constant volt-
age charger
a. Measure the open-circuit voltage prior to
charging.
TIP
Voltage should be measured 30 minutes after
the engine is stopped.
b. Connect a charger and ammeter to the bat-
tery and start charging.
c. Make sure that the current is higher than the
standard charging current written on the bat-
tery.
TIP
If the current is lower than the standard charg-
ing current written on the battery, this type of
battery charger cannot charge the VRLA (Valve
Regulated Lead Acid) battery. A variable volt-
age charger is recommended.
d. Charge the battery until the battery's charg-
ing voltage is 15 V.
TIP
Set the charging time at 20 hours (maximum).
e. Measure the battery open-circuit voltage af-
ter leaving the battery unused for more than
30 minutes.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
ELECTRICAL COMPONENTS
6. Install:
• Battery terminals
7. Connect:
• Battery leads
(to the battery terminals)
ECA
NOTICE
First, connect the positive battery lead "1",
and then the negative battery lead "2".
8. Check:
• Battery terminals
Dirt  Clean with a wire brush.
Loose connection  Connect properly.
9. Lubricate:
• Battery band
Recommended lubricant
Dielectric grease
10.Install:
• Seat
• Side cover (left/right)
Refer to "GENERAL CHASSIS" on page 4-
1.
EASB291353

CHECKING THE RELAYS

Check each switch for continuity with the pock-
et tester. If the continuity reading is incorrect,
replace the relay.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
1. Disconnect the relay from the wire harness.
2. Connect the pocket tester (  1) and bat-
tery (12 V) to the relay terminal as shown.
Check the relay operation.
Out of specification  Replace.
8-60
2
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yz250fxf 2015

Table of Contents