12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
6. Install:
• Battery
7. Connect:
• Battery leads
(to the battery terminals)
ECA
NOTICE
First, connect the positive battery lead "1",
and then the negative battery lead "2".
8. Check:
• Battery terminals
Dirt Clean with a wire brush.
Loose connection Connect properly.
9. Lubricate:
• Battery terminals
Recommended lubricant
Dielectric grease
10.Install:
• Seat
• Side cover (left/right)
Refer to "GENERAL CHASSIS" on page 4-
1.
EASB29B351
CHECKING THE RELAYS
Check each switch for continuity with the pock-
et tester. If the continuity reading is incorrect,
replace the relay.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
1. Disconnect the relay from the wire harness.
2. Connect the pocket tester ( 1) and bat-
tery (12 V) to the relay terminal as shown.
Check the relay operation.
Out of specification Replace.
ELECTRICAL COMPONENTS
Starter relay
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
2
1
Main relay
3
4
2
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Starting circuit cut-off relay
3
4
2
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
8-67
3
R/W
R
Br/W
L/G
4
2
Result
Continuity
(between "3" to "4")
1
L/R
R
Br
R,R/W
Result
Continuity
(between "3" to "4")
1
G/B
L/B
L/G,L/W
1