Progres AGRONIC 4500 Assembly Manual
Hide thumbs Also See for AGRONIC 4500:

Advertisement

ASSEM B LY A ND CO N N ECT IO N MAN UAL
AGRÓNIC 4500
VERSION 1
Sections contained in the manual:
‒ Dimensions
‒ Technical characteristics
‒ Location of the connections
‒ Connection
‒ Installation of options
‒ Recommendations
The Programming, Manual Actions and Query sections
are detailed in the User Manual.
The Parameters and Coding of inputs and outputs
sections are detailed in the Installer Manual.
The Communication Parameters section is detailed in
the Communication Manual.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AGRONIC 4500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Progres AGRONIC 4500

  • Page 1 ASSEM B LY A ND CO N N ECT IO N MAN UAL AGRÓNIC 4500 VERSION 1 Sections contained in the manual: ‒ Dimensions ‒ Technical characteristics ‒ Location of the connections ‒ Connection ‒ Installation of options ‒ Recommendations The Programming, Manual Actions and Query sections are detailed in the User Manual.
  • Page 2 Welcome to the Agrónic 4500 manual. We are pleased to have your experience and skills to carry out the installation of the Agrónic 4500. This document will guide you in the process of installing Agrónic on the farm or electrical panel. Providing details about the dimensions of the controller, and wiring of the different connection options.
  • Page 3: Table Of Contents

    Index Dimensions ......................4 Technical characteristics ..................5 Situation of the connections ................6 3.1. Box format ....................6 3.2. Built-in format ................... 7 Connection ......................8 4.1. Power connection ..................8 4.2. Ground connection ..................8 4.3. Connecting the digital inputs ..............9 4.4.
  • Page 4: Dimensions

    DIMENSIONS Agrónic location In the built-in format, a hole will be made in the front Install the Agrónic at the appropiate height and of the cabinet or desk according to the measurements position for good handling. Avoid as much as possible and it will be held by the screws in the corners, using the direct incidence of the sun, humidity, dust and vi- the four pieces that are suplied with the controller (4...
  • Page 5: Technical Characteristics

    2 TECHNICAL CHARACTERISTICS Overall power supply Voltage 12 Vdc - 24 Vdc Energy consumption Less than 12 W Fuse Entrance Thermal (PTC) 1,1 Amp. at 25 °C, self-resetting Power supply outputs Voltage From 12 a 24 Vdc ó Vac (maximum 30 V) Fuse “R+”...
  • Page 6: Situation Of The Connections

    3 SITUATION OF THE CONNECTIONS 3.1. BOX FORMAT To make the connection in the controller with box The connectors and antennas for the rest of the options format, remove the bottom cover to access the connec- are located on the right side. tors.
  • Page 7: Built-In Format

    Situation of the connections | Built-in format 3.2. BUILT-IN FORMAT In the built-in format, access the rear face located In addition, when there are options installed, there inside the desk or cabinet. Here we find the connectors may be the connectors for the antennas of the for the power supply, the inputs, the outputs for the AgroBee-L options or for the modem of Wi-Fi.
  • Page 8: Connection

    4 CONNECTION The installation must be carried out in accordance with current regulations for electrical installations. The protection of the controller will not be ensured if it is not used as specified in this manual. The Agrónic must be installed far from sources of interference such as frequency inverters, motors or power cables. Sensor and communication cables should never pass next to alternating current cables and should preferably be shielded.
  • Page 9: Connecting The Digital Inputs

    Connection | Connecting the digital inputs 4.3. CONNECTING THE DIGITAL INPUTS Digital inputs Both the digital inputs and the relay outputs are exter- The contacts of the devices connected to the digital nally powered at 12 Vdc or 24 Vac. inputs must be free of voltage.
  • Page 10 Connection | Power connection 24 Vac outputs (220 Vac installation) 12 Vdc outputs (12 Vdc installation) Assembly and connection manual | Agrónic 4500...
  • Page 11: Diesel Enginge Connection

    Connection | Diesel enginge connection 4.5. DIESEL ENGINGE CONNECTION In installations where there is a motorized pump, giving and removing the contact, so the key must be left Agrónic can manage the start and stop manoeuvres. in the rest position. To manage it, it uses four outputs (preheating, contact, A supplementary relay will be inserted in the starting start and stop) and a digital input (oil pressure switch).
  • Page 12: Connection Of The Expansion Modules (Em)

    Connection | Connection of the expansion modules (EM) It may be interesting to have a double sotp system for valve to cut off the fuel supply when there is a possible greater safety, with the electromagnet for a quick and break or incident.
  • Page 13: Installation Of Options

    5 INSTALLATION OF OPTIONS 5.1. DOUBLE VOLTAGE OPTION The dual voltage option is for installations where power The Agrónic can have two functions: comes from a diesel generator. The Agrónic will start the With start and stop management of the diesel engine. In generator when it has to do an irrigation and will stop it this case the diesel control is used with the outputs of when finished.
  • Page 14 Installation of options | Connection of the expansion modules (EM) Diesel engine with generator set with control unit Assembly and connection manual | Agrónic 4500...
  • Page 15: Latch Option

    Installation of options | Latch option 5.2. LATCH OPTION In installations where a very low energy consumption The installer can prepare the controller to use latch is needed, latch valves are usually used. Latch solenoid solenoid valves in the format of two or three wires and valves, also called impulse valves, work by locking their the trip voltage at 12 or 22 volts.
  • Page 16 Installation of options | Latch option 3-wire latch connection This model of solenoid valve has two commons, the On the other hand, the start commons, CM and stop running one (normally red) will be taken to the diode commons CP of the controller and the diode box must box, to one of the terminals marked “Start”, the stop be connected.
  • Page 17: Analog Inputs And Outputs Option

    Installation of options | Analog inputs and outputs option 5.3. ANALOG INPUTS AND OUTPUTS OPTION In installations where it is necessary to read analog sensors logic or analog outputs for fertilization or pressure regulation this option is requiered. Connection of analog inputs and outputs Assembly and connection manual | Agrónic 4500...
  • Page 18: Agrónic Monocable / Radio Option

    Installation of options | Agrónic Monocable / Radio option 5.4. AGRÓNIC MONOCABLE / RADIO OPTION To connect the Agrónic Monocable (EAM) of Agrónic EAM or EAR is 12 meters. The cable cannot be routed Radio (EAR) to the Agrónic 4500, the “RS485 Modbus together with cables with alternating current or near Link”...
  • Page 19: Recommendations

    6 RECOMMENDATIONS • In installations that have a pressure transducer, it Controller location must be galvanically isolated from the pressure • Install the controller at the proper height and pipe, since interference can propagate through it. position for good handling. The tranducer can be attached b means of an in- •...
  • Page 20 Sistemes Electrònics Progrés, S.A. Polígon Industrial, C/ de la Coma, 2 | 25243 El Palau d’Anglesola | Lleida | España Tel. 973 32 04 29 | info@progres.es | www.progres.es R-2448...

Table of Contents