Download Print this page

Scale-Tronix 5002 Operating And Service Manual page 18

Second generation weighing systems

Advertisement

display
"BEEPEr
(audio
beeper).
Press
the "ST"
pushbutton again.
"On" or "OFF" will be displayed.
This may
be changed
by pressing the "RE
CALL"
pushbutton.
Setting this option to "OFF" will eliminate
the
audible
signal
that occurs
when
a front
pane!
pushbutton is pressed or a weight is locked in.
10)
Press the "ST" pushbutton.
If equipped at the
factory with the optional data port or built-in printer the
scale will display "rS-232", indicating the start of the
serial data port options.
If this option is not provided
skip to paragraph
14 below.
The optional serial data
port on the SCALE-TRONIX® second generation scales
is used to send weight data to the built-in printer (if so
equipped) or an external data collection device, such as
a personal computer.
11)
Press
the
"ST"
pushbutton.
The
scale
will
display "OutPuť.
Again press the "ST" pushbutton.
The display will show the currently selected data port
output option.
NOTE:For operation of the internal built-in printer this
must be set at "StPrt1" (SCALE-TRONIX® printer #1).
Setting
the "OutPuf' option to one of the other printer
selections can cause erroneous operation of the scale
and/or printer.
If the optional data port is used for data transmission to
a computer or other device ("OutPuť set to "dAtA"), or
to a an external printer "OutPuť set to IMP.24, IMP-56,
С13110,
ас.)
refer to the more
detailed
addendum
included with your scale which explains setting up the
various data port communication parameters (baud rate,
parity, etc.).
This option may also be set to "OFF", which will disable
the internal printer.
If the printer is disabled, the front
pane! "PRINT" pushbutton will no longer operate and
may
be
covered
with
a
strip
of tape
to
prevent
confusion.
12)
Press
the
"ST"
pushbutton.
The
scale
will
display "PrtUnt' (print units).
Again press the "ST"
pushbutton,
the
"POUNDS"
and
"KILOGRAMS"
annunciators will illuminate to indicate which print units
are selected.
By pressing the "RE CALL" pushbutton
the following selections can be made:
a.) "POUNDS"
and
"KILOGRAMS"
lit:
Print
output
is whatever
unit is selected
on
the
scale's front panel.
This is the normal default
setting.
b.) "KILOGRAMS"
lit:
Prints weight only in
Kilograms regardiess of scale's present front
panel weighing units selection.
e.) "POUNDS" Hit. Prints weight only in Pounds
regardless
of
scale's
present
front
panel
weighing units selection.
Note:
The printing mode is independent of the weight
units option mode.
As an example, if the weighing units
are selected as "POUNDS" only, the print units can be
selected to print in "KILOGRAMS" only.
13)
Press the "ST"
pushbutton.
The scale will
display "PrtOPt' (print option).
By pressing the "RE
CALL"
pushbutton
the
following
selections
can
be
made:
a.)
"PniPrť
(Panel Print):
Weight is printed
when
the front panel
"PRINT"
pushbutton
is
pressed.
This is the normal factory (default)
setting.
b)
"AufPrf'
(Auto
Print):
Weight
is
automatically
printed
when
weight
"lock-in"
occurs.
(Note:
The
front
panel
"PRINT"
pushbutton is still active and may be pressed to
obtain an additional weight ticket.)
14.)
Press the "ST"
pushbutton.
The scale will
display "PC brd" (printed circuit board).
Pressing the
"ST" pushbutton again will display the model number of
the printed circuit board (i.e. "23005°). Another press of
the
"S7™ pushbutton will show the revision level of the
printed
circuit
fe.
"01.
These
are
provided
for
informational trouble-shooting purposes and cannot be
changed in set-up mode.
15)
Pressing
the
"ST"
pushbutton
one
last time
returns the scale to the introductory "SEt-UP" mode.
The scale may be turned off by pressing and holding the
"ON" pushbutton (use the power rocker switch for the
models
5102
and
6202),
or the option
list may
be
run-through another time.
If left alone the scale will
automatically
shut-off after three
(3) minutes
(except
models 5102 and 6202).
(The selected automatic shut-
off time is temporarily lengthened when the scale is
operating in the special "SEt-UP" mode.)
§002, 5102, 5602, 6002, 6102, 6202, 6502, 6702
15

Advertisement

loading

Related Products for Scale-Tronix 5002

This manual is also suitable for:

560251026002670261026202 ... Show all