C-1
The CV-655 can be used to power any of
the following Lincoln Wire feeders:
SEMI-AUTOMATIC WIRE FEEDERS
DH-10
LN-10
LN-7 GMA*
LN-742
LN-7
AUTOMATIC WIRE FEEDERS*
NA-3
NA-5
* European CV-655 models only provide 115VAC for these feeders at the
terminal strip (TS2)
#
"Cold starting for sub-arc cannot be used. (It must be jumpered out. See
Auto Feeder manual)

FIELD INSTALLED OPTIONS

K1482-1 Digital Ammeter/Voltmeter Kit - Installs
easily to the front control panel and provides digital
display of actual welding voltage and amperage while
welding. (Installation instructions are included with the
kit).
K1483-1 Analog Ammeter/Voltmeter Kit - Installs
easily to the front control panel and provides analog
display of actual welding voltage and amperage while
welding. (Installation instructions are included with the
kit).
K1484-1 Dual Feeder Kit - This kit replaces the 14
Pin MS-receptacle panel on the lower case front of the
CV-655. It provides two 14 Pin MS-receptacles and a
built in transfer circuit for connecting and operating
two like-polarity wire feeders. European CV-655 mod-
els can only use 42V feeders with this kit. (Installation
instructions are included with the kit).
K1485-1 Cable Hanger Bracket - Mounts over stan-
dard lift bale of the CV-655 and provides a cable
hanger on both sides of the power source, each side
capable of holding up to 100 ft. of weld cable.
(Installation instructions are included with the kit).
K1486-1 Air Filter Kit - Removable metal filter easily
slides in and out of a bracket which mounts to the
front of the CV-655. Filter is designed to trap 80% of
entering particles which are 5 microns, or larger, in
size. (Installation instructions are included with the
kit).

ACCESSORIES

LN-9*
LN-9 GMA*
LN-23P
LN-25
LN-8*
#
NA-5R
S T R A I G H T P L U G ( 1 4 P I N )
T O P O W E R S O U R C E
CV-655
NOTE: A dirty air filter may cause the thermal protec-
tion of the CV-655 to prematurely activate. Remove
and blow out, or wash and dry, the filter every two
months, or less if in extremely dirty conditions.
Replace if necessary.
Undercarriage (K817P, K842) - The CV-655 is
designed for use with the Lincoln K817P or K842
Undercarriage. Complete installation instructions are
included with each undercarriage. When any of the
undercarriages are installed, the CV-655 lift bail is no
longer functional. Do not attempt to lift the machine
with the undercarriage attached. The undercarriage is
designed for moving the machine by hand only.
Mechanized towing can lead to injury and /or damage
to the CV-655.
REMOTE OUTPUT CONTROL
(K775 or K857 WITH K864 ADAPTER)
An optional "remote output control" is available. This is
the same remote control that is used on other Lincoln
power sources (K775). The K775 consists of a control
box with 28 ft (8.5m) of four conductor cable. This con-
nects to terminals 75, 76, and 77 on the terminal strip
and the case grounding screw so marked with the sym-
bol
on the machine. These terminals are located
behind the cover panel on the lower connection panel of
the CV-655. This control will give the same control as
the output control on the machine.
The K857 has a 6-pin MS-style connector. The K857
requires a K864 adapter cable which connects to the
14-pin connector on the CV-655.
REMOTE CONTROL ADAPTER CABLE (K864)
A "V" cable 12" (.30m) long to connect a K857
Remote Control (6 pin connector) with a wire-feeder
(14-pin connector) and the machine (14-pin connec-
tor). If a remote control is used alone the wire-feeder
connection is then not used.
C-1
C A B L E R E C E P T A C L E ( 6 S O C K E T )
T O :
K 8 5 7 R E M O T E C O N T R O L
C A B L E R E C E P T A C L E ( 1 4 S O C K E T )
T O :
L N - 7 W I R E F E E D E R S