Advertisement

Available languages

Available languages

Quick Links

SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSY-JY09VF MSY-JY13VF
MSY-JY18VF MSY-JY24VF
MSY-JY15VF
OPERATING INSTRUCTIONS
• To use this unit correctly and safely, be sure to read these operating
instructions before use.
For user
English

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric Mr.SLIM MSY-JY09VF

  • Page 1 SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSY-JY09VF MSY-JY13VF MSY-JY15VF OPERATING INSTRUCTIONS For user English MSY-JY18VF MSY-JY24VF • To use this unit correctly and safely, be sure to read these operating instructions before use.
  • Page 2: Table Of Contents

    ● OPERATING INSTRUCTIONS ● ONTENTS n SAFETY PRECAUTIONS n NAME OF EACH PART n PREPARATION BEFORE OPERATION n SELECTING OPERATION MODES n FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT n FAST COOLING OPERATION n SLEEP OPERATION n TIMER OPERATION (ON/OFF TIMER) n EMERGENCY OPERATION n AUTO RESTART FUNCTION n CLEANING...
  • Page 3 AFETY PRECAUTIONS Meanings of symbols used in this manual : Be sure not to do. : Danger of electric shock. Be careful. : Be sure to disconnect the power supply plug : Be sure to follow the instruction. from the power outlet. : Never insert your fi...
  • Page 4 ● OPERATING INSTRUCTIONS ● AFETY PRECAUTIONS WARNING The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer. • Unsuitable detergent may cause damage to plastic material inside the unit, which may result in water leakage.
  • Page 5 AFETY PRECAUTIONS CAUTION Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance. • Inadequate ventilation may cause oxygen starvation. Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike. •...
  • Page 6: Name Of Each Part

    ● OPERATING INSTRUCTIONS ● AME OF EACH PART Indoor unit <JY09/13/15> Front panel Heat exchanger Air inlet Air fi lter (V air fi lter) Air cleaning fi lter (Microparticle catching fi lter) (Electrostatic anti-allergy enzyme fi lter, option) Horizontal vane Operation indicator lamp Air outlet Remote control receiving section...
  • Page 7 AME OF EACH PART Remote controller Signal transmitting section Distance of signal : About 6 m Beep(s) is (are) heard from the indoor unit when the signal is received. * Refer to page 17 for ERROR CODE DISPLAY MODE. Operation display section FAST COOLING button Page 10 Temperature buttons...
  • Page 8: Preparation Before Operation

    ● OPERATING INSTRUCTIONS ● REPARATION BEFORE OPERATION Note: Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on. How to set remote controller exclusively for a par- ticular indoor unit Installing the remote controller A maximum of 4 indoor units with wire- batteries less remote controllers can be set.
  • Page 9: Selecting Operation Modes

    ELECTING OPERATION MODES Note: Operation indicator lamp The operation indicator lamp shows the operation state of the unit. Room Indication Operation state temperature JY09/13/15 JY18/24 The unit is oper- About 2°C or ating to reach the more away from set temperature set temperature The room About 1 to 2°C...
  • Page 10: Fan Speed And Airflow Direction Adjustment

    ● OPERATING INSTRUCTIONS ● AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Up-down Airflow direction Press to select airfl ow direc- tion. Each press changes airfl ow direction in the following order: (AUTO) (SWING) (AUTO) ..The vane is set to the most effi cient airfl...
  • Page 11: Fast Cooling Operation

    AST COOLING OPERATION LEEP OPERATION Press during COOL Press during COOL mode Page 8 to start SLEEP opera- mode page 8 to start FAST COOL- tion. ING operation. • Set temperature will change over time. Fan speed : Exclusive speed for FAST •...
  • Page 12: Timer Operation (On/Off Timer)

    ● OPERATING INSTRUCTIONS ● IMER OPERATION MERGENCY OPERATION (ON/OFF TIMER) When the remote controller cannot be used... Emergency operation can be activated by pressing the emergency operation switch (E.O. SW) on the indoor unit. Each time the E.O. SW is pressed, the operation changes in the following order: Operation indicator lamp...
  • Page 13: Cleaning

    LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Be careful not to touch the metal parts with your hands. • Do not use benzine, thinner, polishing powder, or insecticide. • Use only diluted mild detergents. •...
  • Page 14 ● OPERATING INSTRUCTIONS ● LEANING Air fi lter (V air fi lter) Clean every 2 weeks • • Remove dirt by a vacuum cleaner, or rinse with water. • After washing with water, dry it well in shade. • V air fi lter has a virus-suppressing coating not only to improve air quality but also to eliminate bacteria and viruses. Air cleaning fi...
  • Page 15: When You Think That Trouble Has Occurred

    HEN YOU THINK THAT TROUBLE HAS OCCURRED Even if these items are checked, when the unit does not recover from the trouble, stop using the air condi- tioner and consult your dealer. Symptom Explanation & Check points Indoor Unit The unit cannot be operated. •...
  • Page 16 ● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT TROUBLE HAS OCCURRED Symptom Explanation & Check points Does not cool The room cannot be cooled suffi ciently. • Is the temperature setting appropriate? Page 8 • Is the fan setting appropriate? Please change fan speed to High or Super High.
  • Page 17: Error Code Display Mode

    RROR CODE DISPLAY MODE Error code can be checked on the display of remote controller while the left/upper operation indicator lamp on the indoor unit is blinking. Follow the procedure below to check the error code. Error code check Press to change an error code.
  • Page 18 ● OPERATING INSTRUCTIONS ● RROR CODE DISPLAY MODE Error code of remote controller Object Code Abnormal point None (Normal) Indoor unit Serial signal Indoor control system Room temperature thermistor Indoor coil thermistor Indoor fan motor Outdoor unit Indoor/outdoor communication, receiving error Nonvolatile memory data Diff...
  • Page 19: When The Air Conditioner Is Not Going To Be Used For A Long Time

    HEN THE AIR CONDITIONER ISNOT NSTALLATION PLACE GOING TO BE USED FOR A LONG TIME AND ELECTRICAL WORK Installation place Operate by COOL mode with the Avoid installing the air conditioner in the following highest temperature set or FAN places. •...
  • Page 20: Specifications

    ● OPERATING INSTRUCTIONS ● PECIFICATIONS Model MSY-JY09VF MSY-JY13VF MSY-JY15VF Indoor 280 × 838 × 228 280 × 838 × 228 280 × 838 × 228 Dimensions H × W × D (mm) Outdoor 454 × 660 × 235 454 × 660 × 235 538 ×...
  • Page 21 สารบั ญ ขŒ อ ควรระวั ง เพื ่ อ ความปลอดภั ย ชื ่ อ ของส‹ ว นประกอบต‹ า งๆ การเตรี ย มตั ว ก‹ อ นใชŒ ง าน การเลื อ กโหมดการใชŒ ง าน การปรั บ ทิ ศ ทางและความเร็ ว ของลม การทำงานแบบ...
  • Page 22 คู  ม ื อ การใช ง าน   ข อ ควรระวั ง เพื ่ อ ความปลอดภั ย ความหมายของสั ญ ลั ก ษณ ท ี ่ ใ ช ใ นคู  ม ื อ ฉบั บ นี ้ : หŒ า มปฏิ บ ั ต ิ โ ดยเด็ ด ขาด : ระวั...
  • Page 23 ข อ ควรระวั ง เพื ่ อ ความปลอดภั ย คํ า เตื อ น ผู  ใ ช ง านไม ค วรพยายามล า งเครื ่ อ งปรั บ อากาศภายในบ า นด ว ยตนเอง หากจํ า เป น ต อ งทํ า ความสะอาดภายในตั ว เครื ่ อ ง โปรดติ...
  • Page 24 คู  ม ื อ การใช ง าน   ข อ ควรระวั ง เพื ่ อ ความปลอดภั ย ข อ ควรระวั ง ควรตรวจให แ น ใ จว า พื ้ น ที ่ น ั ้ น จะมี ก ารระบายอากาศที ่ ด ี ข ณะที ่ เ ครื ่ อ งปรั บ อากาศทํ า งานพร อ มกั บ เครื ่ อ งใช ท ี ่ ม ี ก ารเผาไหม •...
  • Page 25 ชื ่ อ ของส ว นประกอบต า งๆ เครื ่ อ งภายในบ า น <JY09/13/15> ตั ว แลกเปลี ่ ย นความรŒ อ น ฝาครอบดŒ า นหนŒ า ช‹ อ งลมเขŒ า แผ‹ น กรองอากาศ (แผ‹ น กรองอากาศ V air filter) แผ‹...
  • Page 26 คู  ม ื อ การใช ง าน   ชื ่ อ ของส ว นประกอบต า งๆ รี โ มทคอนโทรล ส‹ ว นส‹ ง สั ญ ญาณ ระยะที ่ ส ามารถส‹ ง สั ญ ญาณไดŒ : ประมาณ 6 เมตร* เสี...
  • Page 27 การเตร ี ย มต ั ว ก  อ นใช  ง าน หมายเหตุ : ก่ อ นใช้ ง าน: เสี ย บปลั ๊ ก ไฟเข้ า กั บ เต้ า รั บ และ/หรื อ สั บ เบรกเกอร์ ข ึ ้ น การใส...
  • Page 28 คู  ม ื อ การใช ง าน   การเลื อ กโหมดการใช ง าน หมายเหตุ : ไฟแสดงการทํ า งาน ไฟแสดงการทํ า งานจะแสดงสถานะการทํ า งานของเครื ่ อ งปรั บ อากาศ การแสดงการทํ า งาน สถานะการทํ า งาน อุ ณ หภู ม ิ ห Œ อ ง JY09/13/15 JY18/24 เครื...
  • Page 29 การปรั บ ทิ ศ ทางและความเร็ ว ของลม ทิ ศ ทางลมขึ ้ น -ลง กดปุ † ม เพื ่ อ เลื อ กทิ ศ ทางลม เมื ่ อ กดปุ † ม แต‹ ล ะครั ้ ง ทิ ศ ทางลมจะเปลี ่ ย นไปตามลำดั บ ดั...
  • Page 30 คู  ม ื อ การใช ง าน   การทํ า งานแบบ FAST COOLING การทํ า งานแบบ SLEEP กด ขณะอยู ‹ ใ นโหมด COOL หนŒ า 8 กด ขณะอยู ‹ ใ นโหมด COOL หนŒ า 8 เพื ่ อ เริ ่ ม การทำงานแบบ FAST COOLING เพื...
  • Page 31 การตั ้ ง เวลาเป ด /ป ด เครื ่ อ ง ระบบการทํ า งานฉุ ก เฉิ น (การตั ้ ง เวลา ON/OFF) เมื ่ อ ไม ส ามารถใช ง านรี โ มทคอนโทรลได … ท‹ า นสามารถใชŒ ร ะบบการทํ า งานฉุ ก เฉิ น ไดŒ โ ดยการกดสวิ ต ช ก ารทํ า งานฉุ...
  • Page 32 คู  ม ื อ การใช ง าน   การทํ า ความสะอาด คํ า แนะนํ า : • ป ด สวิ ต ช แ หล‹ ง จ‹ า ยไฟ หรื อ สั บ เบรกเกอร ล งก‹ อ นทํ า ความสะอาด •...
  • Page 33 การทํ า ความสะอาด แผ น กรองอากาศ (แผ น กรองอากาศ V air filter) ทํ า ความสะอาดทุ ก 2 สั ป ดาห • กํ า จั ด สิ ่ ง สกปรกดŒ ว ยเครื ่ อ งดู ด ฝุ † น หรื อ ลŒ า งออกดŒ ว ยนํ ้ า •...
  • Page 34 คู  ม ื อ การใช ง าน   เมื ่ อ ท า นคิ ด ว า เครื ่ อ งปรั บ อากาศของท า นมี ป  ญ หา หากตรวจสอบทุ ก ข อ แล ว แต ต ั ว เครื ่ อ งยั ง ทํ า งานไม ป กติ ให ห ยุ ด การใช ง านและปรึ ก ษาตั ว แทนจํ า หน า ย อาการ...
  • Page 35 เมื ่ อ ท า นคิ ด ว า เครื ่ อ งปรั บ อากาศของท า นมี ป  ญ หา อาการ รายละเอี ย ดและจุ ด ตรวจสอบ อากาศไม เ ย็ น เครื ่ อ งปรั บ อากาศทํ า ความเย็ น ไม‹ เ พี ย งพอ •...
  • Page 36 คู  ม ื อ การใช ง าน   โหมดแสดงรหั ส ความผิ ด ปกติ สามารถตรวจสอบรหั ส ความผิ ด ปกติ บ นหน า จอของรี โ มทคอนโทรลได ใ นขณะที ่ ไ ฟแสดงการ ทํ า งานด า นซ า ย/บนของตั ว เครื ่ อ งภายในบ า นกํ า ลั ง กะพริ บ ทํ...
  • Page 37 โหมดแสดงรหั ส ความผิ ด ปกติ รหั ส ความผิ ด ปกติ ข องรี โ มทคอนโทรล รายการ รหั ส จุ ด ที ่ ผ ิ ด ปกติ ไม‹ ม ี (ปกติ ) เครื ่ อ ง สั ญ ญาณแบบอนุ ก รม ภายในบŒ า น ระบบควบคุ...
  • Page 38 คู  ม ื อ การใช ง าน   เมื ่ อ ไม ไ ด ใ ช เ ครื ่ อ งปรั บ อากาศ สถานที ่ ต ิ ด ตั ้ ง และงานทาง เป น เวลานาน ด า นไฟฟ า สถานที...
  • Page 39 ข อ มู ล จํ า เพาะ รุ  น MSY-JY09VF MSY-JY13VF MSY-JY15VF เครื ่ อ งภายในบ า น 280 × 838 × 228 280 × 838 × 228 280 × 838 × 228 ขนาด สู ง × กว า ง × ลึ ก (มม.) เครื...
  • Page 40 HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN VG79Y762H01...

Table of Contents