Haier AW052MUCHA Installation Manual page 23

Monobloc air-to-water heat pump system
Hide thumbs Also See for AW052MUCHA:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Installation instruction
AW112MXCHA
AW142MXCHA
AW162MXCHA
AW11NMXCHA
AW14NMXCHA
AW16NMXCHA
180
(4) Drain work of the outdoor unit
In case drain work on your outdoor unit is neccessary, follow the guidelines below.
• One drain outlets are provided in the bottom plate of unit (drain plug and drain hose are field supply).
• In cold areas, do not use a drain hose with the unit. Otherwise,drain water may freeze and block the drain. In case
the use of a drain hose is unavoidable for one reason or another, it is recommended to install a heater tape in order to
protect drain from freezing.
• Make sure the drain works properly.
D
A 783
17
E
B 288
A leg pitch1
B leg pitch2
C leg pitch3
D Drain hole
E Bottom frame