3-2,
CONVERGENCE
2.
When the V.STAT magnet is moved in the direction of
¢
Set BRIGHTNESS control to minimum,
®
-\_®
B
B
¢
Feed in dot pattern.
\
(1) Vertical Static Convergence
R
|
R
|
V. STAT magnet
If the blue dot does not converge with red and green dots,
Fig. 5
perform the following steps:
Move BMC magnet (a) to correct insufficient H.static
1.
Adjust V. STAT magnet to converge red, green and blue
convergence.
dots in the center of the screen. (Vertical movement)
Rotate BMC magnet (b) to correct insufficient V.static
e
Tilt the VSTAT magnet and adjust static convergence
convergence.
to open or close the V.STAT magnet.
In either case, repeat Beam Landing Adjustment.
BMC magnet
Fig. 6