Download Print this page

CAMDEN CX-WC16PS Series Installation Instructions Manual page 3

Advertisement

WC16PS SERIES RESTROOM CONTROL
I NSTA LLAT I O N I N S T RU C T I O N S
Display (M)
H, then 1
d, then 1
H, then 2
d, then 2
H, then 3
d
Input delay on Activate. If other than 0.0 is selected, the input must
A
be held in for the time period chosen before the CX-33 will activate.
1
Set Dry Input 1 to activate on normally open or normally closed contact.
2
Set Dry Input 2 to activate on normally open or normally closed contact.
3
Set Dry Input 3 to activate on normally open or normally closed contact.
4
Set Dry Input 4 to activate on normally open or normally closed contact.
5
Set Wet Input 5 to activate on normally open or normally closed contact.
Mounting
The Sure-Wave™ may be mounted in single or double gang electrical boxes, and 4 x 4 boxes.
NOTE: The sealing gasket (included) is recommended for outdoor or wet locations.
If using with Automatic doors install in accordance with ANSI A156.10 / A156.19.
Select from one of the following mounting subsections :
Page 3 of 13
Description ( Mode you are in)
Relay 1 Hold Time
Relay 2 Delay Time
Relay 2 Hold Time
Relay 3 Delay Time
Relay 3 Hold Time
Sets the display ON or OFF during operating mode
Parameters ( 1-15 )
0.0 to 50 seconds
0.0 to 15 seconds
0.0 to 50 seconds
Depends on Mode
0.0 to 50 seconds
ON or OFF
0.0 to 10 seconds
N/O OR N/C
N/O OR N/C
N/O OR N/C
N/O OR N/C
N/O OR N/C

Advertisement

loading

This manual is also suitable for:

Cm-331/42ws-sglrCm-325/42wsCm-331/43s-sglr