Installation Preparation; Cabinet Dimensions; Water Supply Requirements; Drain Requirements - Sharp SDW6506JS Installation Manual

Hide thumbs Also See for SDW6506JS:
Table of Contents

Advertisement

INSTALLATION PREPARATION

CABINET DIMENSIONS

• The cabinet opening must be at least 24" deep.
• The cabinet opening must be between 34" and 35" in height.
90˚
34" min.
to 35"
max.
13
22
/
"
16
min.
1
5
/
"
2
3
1
/
"
4
1
3
/
"
2
3
1
/
"
4
FIGURE A
CLEARANCES
When installed in a corner, allow 2" minimum clearance between
dishwasher and adjacent cabinets, walls or other appliances. Allow
27" minimum clearance from the front of the dishwasher for door
opening. See Figure B.
Dishwasher
Clearance for door
opening 2" minimum
FIGURE B
90˚
18"
3"
3"
3
1
/
"
4
3
1
/
"
4
13
23
/
"
16
Countertop
27"

WATER SUPPLY REQUIREMENTS

• Water pressure from the hot water supply line must be between
20-120 psi (138-862 kPa).
• Water heater that is adjusted to a water temperature of 120°F to
150°F (49°C to 65.5°C).
• A copper tubing water line (minimum
at least 24" from the rear wall must be routed to connect to the
front-left side of the dishwasher.
• It is strongly recommended that a hand shut-off valve be installed
in an accessible location, such as under the sink.

DRAIN REQUIREMENTS

• Follow local codes and ordinances.
• The drain hose must not be longer than 10 feet in length.
• Do not connect drain lines from other devices to the dishwasher
drain hose.
• The dishwasher must be connected to waste line with an air
gap (not supplied) or 32" minimum high drain loop (depending
on local codes and ordinances) to prevent back flow into the
dishwasher.
• Air gap must be used if waste tee or disposer connection is less
than 18" above the floor to prevent siphoning.
DRAIN PREPARATION
The type of drain installation depends on answers to the following
questions:
• Do local codes or ordinances require an air gap?
• Will waste tee or disposer connection be less than 18" above
the floor?
• Will installation have a drain loop less than 32" above the floor?
If the answer to ANY of the 3 questions above is YES, Method 1
MUST be used. Otherwise, either Method 1 or Method 2 may be used.
An air gap MUST BE USED if the drain hose is
CAUTION
connected to waste tee or disposer lower than 18" above the floor.
Failure to provide the proper drain connection height with air gap
or 32" minimum high drain loop will result in improper draining of
the dishwasher. Figure C or Figure D.
METHOD 1 – AIR GAP WITH WASTE TEE OR
DISPOSER
5
3
/
" in diameter) extending
8
FIGURE C

Advertisement

Table of Contents
loading

Table of Contents