Reimers JR Series Instruction Manual

Reimers JR Series Instruction Manual

Steam boilers

Advertisement

4407 Martinsburg Pike
Clear Brook, VA 22624
USA
JJ­ and JG­Steam Boiler Models
Reimers Electra Steam, Inc. 04/21/2023
Phone: 540­662­3811
Fax: 540­665­8101
email: sales@reimersinc.com
web: www.reimersinc.com
Instructions Manual
PAGE 1
_______
MODEL:
________
SERIAL#:
JR06 Manual
REV 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JR Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Reimers JR Series

  • Page 1 _______ MODEL: ________ SERIAL#: 4407 Martinsburg Pike Phone: 540­662­3811 Clear Brook, VA 22624 Fax: 540­665­8101 email: sales@reimersinc.com web: www.reimersinc.com JJ­ and JG­Steam Boiler Models Instructions Manual Reimers Electra Steam, Inc. 04/21/2023 PAGE 1 JR06 Manual REV 3...
  • Page 2: Table Of Contents

    Important Safety Information........5 Installation..............6 Location..............6 Water Supply..............7 Safety Relief Valve.............7 Electrical..............7 Operation..............7 Boiler Startup..............7 Boiler Blowfoff.............8 Safety Valve Test............8 Element Replacement and Cleaning......8 Gauge Glass Replacement........8 Troubleshooting............10 Parts Lists..............13 Reimers Electra Steam, Inc. 04/21/2023 PAGE 2 JR06 Manual REV 3...
  • Page 3: Features And Specifications

    100psi. Please note that all information provided within this brochure is approximate and subject to change without notice. Please contact Reimers Electra Steam, Inc. with any questions regarding the specifications or dimensions detailed within. Reimers Electra Steam, Inc. 04/21/2023...
  • Page 4: Limited Warranty Information

    Claims against carriers for damage in transit must be filed by the buyer. Reimers liability, if any, will not exceed the price of Reimers products claimed to be defective.
  • Page 5: Important Safety Information

    4. MODIFICATION/MISUSE: This boiler has been designed and constructed in accordance with the ASME Boiler and Pressure Vessel Code. Any modification or misuse can result in a dangerous situation. Reimers Electra Steam, Inc. is not liable for any product that has been modified or improperly used.
  • Page 6: Installation

    1. Installation REIMERS ELECTRA STEAM, INC. boilers are heated by one or more immersion type heating elements. Automatic controls are provided to maintain pre­set operating pressure and proper water supply. Safety features include automatic low water cutoff, automatic pressure control, safety valve and visible water level gauge. Each boiler is manufactured in accordance with the ASME I Power Boiler Code Standards and is individually inspected and stamped by an authorized National Board Insurance Inspector.
  • Page 7: Water Supply

    Observe the pressure gauge while pressure builds up, until working pressure is reached. The working pressure should have been factory set to your specification. However, if you wish to change the working pressure setting, proceed as follows. Reimers Electra Steam, Inc. 04/21/2023 PAGE 7 JR06 Manual REV 3...
  • Page 8: Boiler Blowfoff

    • Permit the valve to “slap” washers. shut. If a leak occurs, repeat this test and if necessary, replace the valve. Reimers Electra Steam, Inc. 04/21/2023 PAGE 8 JR06 Manual REV 3...
  • Page 9 Reimers Electra Steam, Inc. 04/21/2023 PAGE 9 JR06 Manual REV 3...
  • Page 10: Troubleshooting

    Ensure that the boiler is cold and has no pressure. WARNING Electrical trouble shooting must be performed by a qualified electrician. If troubleshooting did not resolve problem, please contact your local distributor/mechanical contractor Reimers Electra Steam, Inc. 04/21/2023 PAGE 10 JR06 Manual REV 3...
  • Page 11 Reimers Electra Steam, Inc. 04/21/2023 PAGE 11 JR06 Manual REV 3...
  • Page 12 Reimers Electra Steam, Inc. 04/21/2023 PAGE 12 JR06 Manual REV 3...
  • Page 13: Parts Lists

    5. Parts list for JJ and JG Boiler Models (JR­Series) Use Reimers replacement parts. All components are designed and approved to be used in this WARNING Underwriters Laboratories listed and ASME National Board Stamped boiler. Failure to do so may cause serious injury or death.

This manual is also suitable for:

JjJgJj steamJg steam

Table of Contents