5.2. Type Tests and Environmental Conditions

Environmental
phenomena
ESD
Fast transients
Surge
Power frequency
magnetic field
Radiated RF
immunity
Conducted RF
immunity
Radiated RF emission
Conducted RF
emission
Insulation resistance
Dielectric strength
Table 10. EMC and electrical conditions
30
Basic
Description
standard
EN 61000-4-2
Enclosure
EN 61000-4-4
DC power port
Ethernet ports
Antenna ports
EN 61000-4-5
DC power port
Ethernet ports
Antenna ports
EN 61000-4-8
Enclosure
EN 61000-4-3
Enclosure
EN 61000-4-6
DC power port
Ethernet ports
Antenna ports
EN 55032
Enclosure
EN 55032
DC power port
Ethernet ports
EN 50155
Power port (DC)
to all other ports
EN 50155
Power port (DC)
to all other ports
Ibex-RT-330-5G Series
Test levels
Contact: ±6 kV
Air: ±8 kV
± 2 kV, direct coupling
± 2 kV, capacitive coupling clamp
L-E: ± 1 kV, 12 Ω, 9 µF, 1.2/50 µs
L-E: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs
L-L: ± 1 kV, 12 Ω, 9 µF, 1.2/50 µs
L-L: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs
L-E: ± 1 kV, 2 Ω, 18 µF, 1.2/50 µs
300 A/m continues, DC, 16.7 Hz, 50 Hz,
60 Hz
20 V/m, 80% AM (1kHz) at 80 MHz to 6
GHz
30 V/m, PM 200 Hz square at 380 MHz to
385 MHz
30 V/m, PM 200 Hz square at 390 MHz to
395 MHz
3 V/m, PM 200 Hz square at 104, 136, 165,
200, 260, 330, 430, 560, 715 ±1, 920 ±1
MHz
10 V, 80% AM (1 kHz) from 0.15 to 80
MHz
Class B
Class B
> 100 MOhm
750 VDC, 60 s

Advertisement

Table of Contents
loading

This manual is also suitable for:

Westermo ibex-rt-330-5g-lv3629-0330