Installation; Mounting; Factory Reset - IBEX Westermo -RT-330-5G Series Manual

Table of Contents

Advertisement

4. Installation

4.1. Mounting

The product is fixed with the four fixing points located at the corners of the product. M5
or M6 screws are used for the fixation of the product. The screws are tightened with min.
3.0 Nm (fixing screw ISO 898/1, quality class 8.8).
NOTICE
All four specified fixing points must be used for fixing. The installation
surface should be flat to have all fixing points connected to the surface.
NOTE
For indoor installation, consider additional protection against dust to
ensure proper heat dissipation.
NOTE
For outdoor installation, consider additional protection against sun
radiation, dust and dirt to optimize ambient temperature range.
NOTE
Unused connectors must be covered by a protective cap (delivered with
the product), tightened to the specified torque in order to fulfill the
specified ingress protection code.

4.2. Factory Reset

To reset the product into factory default settings, a reset adapter is needed which is
plugged into one of the Ethernet ports X1 or X2 during startup.
Art. no.
Description
3623-0799
Factory Reset Plug, X-coded
Factory reset procedure
1.
Plug the factory reset adapter to one of the Ethernet interfaces.
20
Ibex-RT-330-5G Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

Westermo ibex-rt-330-5g-lv3629-0330

Table of Contents