5
Mark the fixing holes in the required positions and secure using suitable fixings.
Note:
The valve must be installed on a flat surface.
Mounting on a Horizontal Surface
6
Connect the hot and cold inlet supply pipework to the digital mixing valve.
Note:
DO NOT use any type of jointing paste or compound on any pipework or fittings
supplying the digital shower valve. These can build up within the product and reduce
the performance or cause early failure.
Note: Only use suitable 15mm pipework when connecting to the push-fit connectors.
You must use appropriate adapters (not supplied) for 1/2" pipework. 15 mm copper
pipework must be used. Chromed copper, stainless steel or barrier pipe is not suitable
for these push fit connectors.
Note:
The inlet pipework must be flexible enough to allow 25 mm movement to enable
filters to be removed for cleaning and for maintenance of the internal components.
Failure to achieve this may result in service and repair not being able to be carried out.
Note:
Flush pipework before connecting inlet pipes to digital mixing valve. Failure
to flush pipework may cause debris to block filters an impair product performance.
Isolating valves must be installed to both inlets (supplied) and it is recommended to
fit isolators on the outlet, close to the digital mixing valve for ease of maintenance.
Note:
The direction of the arrow on the isolation valve indicates direction of flow.
Run the pipes from the mixed water outlets on the digital mixing valve to the proposed
siting for the shower hose outlet, and overhead fixed arm, depending on the system
chosen.
Mounting on a Vertical Surface
26