Every effort has been made to ensure the accuracy of the features and techniques presented in this publication. However, Renu Electronics and its affiliates accept no responsibility and offer no warranty whether expressed or implied, for the accuracy of this publication.
1.3 Related Documents You can refer the following documents about this reference guide: Datasheet 1.4 Contacting Renu Electronics For any support, you can reach Renu Electronics support team in any of the following ways: Website www.renuelectronics.com Email support@renuelectronics.com User Manual...
This user manual gives a detailed information regarding the hardware specifications, operating conditions, installation, mounting and wiring. All the information published in this manual is produced and governed by Renu Electronics Pvt. Ltd. and is protected by the Indian Copyright Act.
Safety Precautions 3.1 Before You Start Renu Electronics Pvt. Ltd. is not responsible or liable for any indirect or consequential damage resulting from the use of this product. The user should check and confirm the suitability of the product before using it in any specific application.
WP2 Lite Web Panel Series 3.2 Safety Precautions This section of the manual provides information that is critical regarding safety and therefore the user is advised to go through the information in detail before installing the product. Users contact RENU Electronics’...
Page 8
WP2 Lite Web Panel Series Intended Users Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. Renu Electronics assumes no responsibility for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to...
WP2 Lite Web Panel Series Chapter 4 Product Overview This section of the manual provides an overview of Web HMI series products, its front and back view, installation details, dimensional details, mounting method and details. This section contains the following topics: ...
WP2 Lite Web Panel Series 4.1.3 Product Dimensions This section of the manual provides dimensional details of Web HMI series products. All the dimensions shown below are measured in mm. WP2043TN Plus WP2070TN Plus WP2101TN Plus User Manual Page 10 of 29...
WP2 Lite Web Panel Series 4.1.4 Minimum Clearances Maintain a minimum clearance of 2” from enclosure walls, wires and other adjacent devices on all sides for adequate ventilation. Plan for adequate space around the product and inside the enclosure for ventilation and cabling. Take into consideration the heat produced by other devices in the enclosure.
WP2 Lite Web Panel Series 4.2 Device Connectivity This product is a display unit that uses a Micro browser to act as a Web client to visualize internal contents of PLCs and other devices that run Web servers on the same Intranet. After turning on web panel, user need to set up its display and Micro browser settings.
WP2 Lite Web Panel Series Chapter 5 Product Specifications This section of the manual provides detailed specifications of Web HMI series products, ordering part numbers, operating conditions, environment and approvals. This section contains the following topics: Product Nomenclature Display Specifications ...
WP2 Lite Web Panel Series 5.2 Display Specifications Web HMI series products support high quality color TFT display range. Size: 4.3" Color TFT, WQVGA Web Panel Analog Resistive Touch Screen Resolution: 480 x 272pixels Colors: 16M Brightness: 400cd/m Backlight life: 30,000Hrs. Size: 7”...
WP2 Lite Web Panel Series 5.3.1 Power Rating Unit Voltage Current Wattage WP2043TN Lite 24VDC 250mA WP2070TN Lite 24VDC 300mA 7.2W WP2101TN Lite 24VDC 350mA 8.4W 5.4 Communication Interfaces This section provides detailed information regarding various communication interfaces supported by the Web HMI series. Interfaces WP2043TN Lite WP2070TN Lite...
WP2 Lite Web Panel Series 5.5 Environmental Specifications and Approvals Feature Specifications Operating Temperature 0 to 50°C Storage Temperature -20 to 85°C Relative Humidity 10 to 95% non-condensing Shock IEC 60068-2-27 25g, 11ms, 6 shocks per axis, total 18 shocks (X, Y, Z) Vibration IEC 60068-2-6...
WP2 Lite Web Panel Series Chapter 6 Getting Started This section contains the following topics: Supported devices What do we need to get started? Cable and Connector Getting started with the Web HMI 6.1 Supported devices ...
Page 18
WP2 Lite Web Panel Series Immediately after switching on the device, the view for calibrating the touch screen appears. Press the screen to start the touchscreen calibration routine. Press 'Settings' ☼ to access the configuration menu of the 4BASIC applications product family.
WP2 Lite Web Panel Series 6.4 Getting started with the Web HMI 6.4.1 Settings Menu Settings Description MicroBrowser and Used to enter the network configuration of the panel. Network Settings Advance Settings Used to set advanced settings. Info Used to show various information about the panel. Firmware Update Used to update the Firmware.
WP2 Lite Web Panel Series 6.4.2 MicroBrowser and Network Settings Settings Description The field 'Host' contains the IP address of the PLC or web server. Host Enter the IP-Address or hostname of the PLC or web server. Example: “192.168.1.22” Check the accessibility of your configured PLC by pressing the 'Ping' button.
Page 21
WP2 Lite Web Panel Series Description Settings To configure a static IP address, DHCP, subnet mask, and gateway. Press the DHCP button , the change is indicated DHCP by the button Choose whether the IP address of the panel should be static or dynamic.
WP2 Lite Web Panel Series 6.4.3 Advanced Settings The advanced settings are displayed on five pages. The default settings are set so that the devices can be used without modification. Press the Advanced Settings button to access the configuration menu. Advanced Settings / Page 1 Settings Description...
Page 23
WP2 Lite Web Panel Series Advanced Settings / Page 2 Settings Description The 'Check project update' setting is used to check periodically for HMI updates. This setting is set in minutes. N" means never/disabled. In the factory setting, it is set to "N". We change it to 1 minute by clicking on the button Check project update The 'Check project update' setting defines the refresh time...
Page 24
WP2 Lite Web Panel Series Advanced Settings / Page 3 Settings Description With “Reset” you can reset the password for fleet Remote Access Password management to the default settings. Next Button Press button to go to Advanced Settings page 4. Advanced Settings / Page 4 Settings Description...
Page 25
WP2 Lite Web Panel Series Advanced Settings / Page 5 Settings Description With option Date / Time Settings, you can set date and Date/Time Settings time of system. Back Button Press button to return to the Settings menu User Manual Page 25 of 29...
WP2 Lite Web Panel Series 6.4.4 Info Press the "Info" button to access the page with information about the main components and parameters. A read-only page with information about the main components and parameters. Settings Description The Firmware version of the panel. Firmware version Read your current firmware and check if a new firmware is available.
WP2 Lite Web Panel Series 6.4.5 Firmware Update Settings Description The panel will look on the internet if new firmware is available. Check for Update Requirements: The panel is connected to the internet and a Online DNS server is configured. The panel will look for a specified host if new firmware is available.
WP2 Lite Web Panel Series 6.4.6 Load Default Settings Settings Description This option allows you to restore the default settings. You Load Default Settings may need to recalibrate the touchscreen afterwards. User Manual Page 28 of 29...
WP2 Lite Web Panel Series Index intended audience ..........4 mediawide contact ..........4 before you started ..........6 related documents ..........4 safety precautions ..........7 product overview ........... 9 grounding ............11 installation of the web hmi product....9 getting started .............
Need help?
Do you have a question about the WP2 Lite Series and is the answer not in the manual?
Questions and answers