Maintenance
Replacing filter cartridges
CAUTION
Risk of personal injury
If a filter is opened without first relieving pressure
from the air filter station, personal injuries could
be caused by rapidly or suddenly escaping
compressed air of the air filter station.
Only replace filter cartridge when the air filter
station is without pressure.
Air filter station 60
A
B
1 Close ball valves (A).
2 Depressurize the air filter station 60 by opening
the relief valve (B) at the fine filter.
3 Unscrew pipe (C) for the condensate discharge.
38
A
C
Instructions for use Air filter station 60/190 Pressure-reducing station 100/300
Replacing the fine filter cartridge
D
C
1 Unscrew filter housing (C) by hand.
2 Unscrew the fine filter cartridge (D) and dispose
of in accordance with the local regulations.
3 Screw in a new fine filter cartridge.
4 Screw together the filter housing (C) and make
it hand-tight.