Page 1
Original Instructions Tina 10A/B/C Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety...
Page 2
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted.
Maintenance ................................8 Testing of the safety functions ..........................8 Troubleshooting ................................ 8 Operation ............................9 LED indication ................................9 Information output signal attributes........................... 9 Technical data ..........................10 Dimensions ................................12 EC Declaration of conformity ....................... 13 2TLC010042M0201 rev.B www.abb.com/jokabsafety...
Introduction Scope The purpose of these instructions is to describe the adaptor units Tina 10A/B/C and to provide the necessary information required for installation and operation. Audience This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: •...
Vital safety module or Pluto safety-PLC. Tina 10A, -B and -C are used to adapt Orion or Focus light beams and light curtains with OSSD outputs to the DYNlink safety circuit. This also enables complete external interconnections using cables with M12 connectors only, which reduces the cabling to and connections in the apparatus enclosure.
Orion2 Base Orion2 Extended Smile 11RO2, 2TLA022316R3100 Orion3 Extended Orion3 Base Smile 11RO3, 2TLA022316R3200 ― Orion1 Extended Cable between Orion and Tina 10A/B/C depending on Orion model Orion Cable, order code Tina 10A/C Tina 10B √ ― M12-CTO1BA, 2TLA022315R3000 Orion1 Base ―...
The OSSD connections shall not be used for purposes other than intended. All loading or tampering with loops can lead to serious risk of life. Caution! All cable colours according to ABB Jokab Safety standard cables. The use of shielded cable is mandatory between this unit and the rest of the safety circuit. Connection examples 2TLC010042M0201 rev.B...
(EN 62061:2005+A2:2015). In case of breakdown or damage to the product, contact the nearest ABB Jokab Safety Service Office or reseller. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel.
Low High Information output signal switch delay Delay for switching information output signal ~ 160 ms ~ 2 ms Warning! The information output signal is not a failsafe signal and should never be used for the safety purpose(s). 2TLC010042M0201 rev.B www.abb.com/jokabsafety...
35 to 85 % (with no icing or condensation) Housing material Connector Tina 10A v2: M12 8-pole female, M12 5-pole male Tina 10B v2: M12 8-pole female, M12 5-pole female, M12 5-pole male Tina 10C v2: M12 8-pole female, M12 5-pole female, M12 5-pole male...
Page 11
Certificate Pollution degree Altitude 2000 m (max) Humidity 80% max for temperatures up to 31°C Electrical supply 24 VDC, 25 mA Indoor use statement For indoor use only Temperature -10 to 55°C 2TLC010042M0201 rev.B www.abb.com/jokabsafety...
Dimensions Tina 10A 11,2 46,5 13,4 Tina 10B 11,2 46,5 13,4 Tina 10C 11,2 46,5 13,4 Note: All measurements in millimetres. 2TLC010042M0201 rev.B www.abb.com/jokabsafety...