Toshiba MCY-MHP0506HT-C Service Manual page 158

Table of Contents

Advertisement

Step Component
14
PMV coil
1. Detachment
1) Remove the front panels, and upper panel.
[Step.1]
2) Remove the connector connected between the
interface P.C. board and PMV coil.
CN300 ...PMV coil (6P: white)
3) Remove the lead wire from the lead wire clamp
(1 position) and the banding band (1 position).
(Fig 14-1)
4) Rotate the coil, and remove while pulling it up
after the fingernail is removed. (Fig. 14-2)
2. Attachment
1) Match the positioning extrusion of the coil
surely to the concavity of PMV body to fix it.
CAUTION
Using a banding band on the market, be sure
to fix the lead wire.
Procedure
157
Remarks
(Fig. 14-1)
PMV body
PMV coil
Rotate the coil, and remove
while pulling it up after the
fingernail is removed.
(Fig.14-2)
PMV coil and body
Lead wire clamp
(1 position)
Banding band
(1 position)
Attach the PMV coil
lead wires so they
face the "right" side
of the set.