Fault
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
Appliance is not cooling,
temperature display and light
are lit.
36
Possible cause
The evaporator (refrigeration
generator) in the NoFrost
system is covered in thick ice
and can no
longer be defrosted fully
automatically.
Showroom mode is
switched on.
Remedial action
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance. Fig. *
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
Hold down alarm button, Fig "/5, for
10 seconds until an acknowledgement signal
sounds.
After a short time check whether your
appliance is cooling.