Drive Housing Replacement - Graco 395 Repair Manual

Airless sprayers
Hide thumbs Also See for 395:
Table of Contents

Advertisement

Drive Housing Replacement

CAUTION
Do not drop gear cluster (44) and (40) when remov-
ing drive housing (42). Gear cluster may stay en-
gaged in motor front end bell or drive housing.
Disassembly
1.
Relieve pressure; page 4.
2. Remove two screws (12) and pump rod cover (70).
3. Remove pump (41); Displacement Pump Re-
placement, page 21.
4. Fig. 12. Remove two screws (12) and shroud (23).
A
Fig. 12
5. Remove two screws (12) and cover (22).
6. Remove four front screws (47).
7. Pull drive housing (42) off of motor (54).
Assembly
1. Fig. 12. Push drive housing (42) onto motor (54).
2. Install four front screws (47).
3. Install cover (22) with two screws (12).
4. Install shroud (23) with two screws (12).
5. Install pump (41); Displacement Pump Replace-
6. Install pump rod cover (70) with two screws (12).
12
23
54
40
ti2570b
ment, page 21.
7
44
47
42
47
22
12
12
70
19