Usb-Pmbus Adapter; Connection Of Flex Kep 910 17 Usb-Pmbus Adapter; Power-Up And Power-Down Instructions; Power-Up Instruction - Flex ROA128 6016 User Manual

Table of Contents

Advertisement

Test Board User Guide BMR47401
3

USB-PMBus adapter

The USB-PMBus adapter used with this board is the Flex KEP 910 17.
3.1

Connection of Flex KEP 910 17 USB-PMBus adapter

Connect the Flex KEP 910 17 USB-PMBus adapter to the PMBus
header, see position 5 in Figure 1a.
4

Power-up and Power-down Instructions

4.1

Power-up instruction

Before power up, read the following table to make sure the module works in the
best condition.
Note: The default switching frequency (f
output voltage higher than 1.8V, frequency shall be changed, f
be done by using "Flex Power Designer" software tool.
28701-ROA1286016 Rev A
16
Diode for input anti-reverse protection
17
Positions for populating Flex electronic load, ROA128 5552.
18
Positions for additional input ceramic capacitors
19
Positions for additional output ceramic capacitors
2021/4/25
) is 500kHz, if the module work with
sw
change should
sw
7 (20)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bmr474Bmr4742001

Table of Contents