Range
S37
decimal
0–19
S38
decimal
0–23
S42
decimal
0–1
Multi-Tech Systems, Inc. AT Commands Reference Guide (PN S000272E)
Default
Description
0
Sets the maximum V.34 "upstream" speed at which the modem
attempts to connect.
Value
Speed
0
maximum modem speed
1
reserved
2
1200/75 bps
3
300 bps
4
reserved
5
1200 bps
6
2400 bps
7
4800 bps
8
7200 bps
9
9600 bps
10
12000 bps
11
14400 bps
12
16800 bps
13
19200 bps
14
21600 bps
15
24000 bps
16
26400 bps
17
28800 bps
18
31200 bps
19
33600 bps
1
Sets the maximum 56K "downstream" speed at which the modem
attempts to connect. The default maximum speed is 56K bps.
Note: When using V.34 or V.32 client-to-client connections in poor
conditions, setting S38=0 may result in better performance.
Value
Rate
0
56K disabled
1
56K autorate
2
28000 bps
3
29333 bps
4
30666 bps
5
32000 bps
6
33333 bps
7
34666 bps
8
36000 bps
9
37333 bps
10
38666 bps
11
40000 bps
12
41333 bps
13
42666 bps
14
44000 bps
15
45333 bps
16
46666 bps
17
48000 bps
18
49333 bps
19
50666 bps
20
52000 bps
21
53333 bps
22
54666 bps
23
56000 bps
1
Enables/disables the 56K auto rate. When 56K auto is
disabled, fallback to V.34 is also disabled. 0 = disable; 1 =
enable.