  • Page 1 PSEN ma1.3p-22 PSEN sensor technology Operating Manual-22148-EN-05...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Requirements and connection to evaluation devices ............Installation ..........................Adjustment ..........................Periodic test ........................... Dimensions in mm ......................... Technical details ........................Safety characteristic data ......................Order reference ........................System ............................Accessories ..........................EC declaration of conformity ....................Operating Manual PSEN ma1.3p-22 22148-EN-05...
  • Page 4: Introduction

    PSEN ma1.3p-22 Introduction Validity of documentation This documentation is valid for the product PSEN ma1.3p-22. It is valid until new document- ation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in- terference. Operating Manual PSEN ma1.3p-22 22148-EN-05...
  • Page 6: Safety Regulations

    Disposal In safety-related applications, please comply with the mission time T in the safety-related characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSEN ma1.3p-22 22148-EN-05...
  • Page 7: For Your Safety

    LED will light. The safety switch is designed for applications in series connections. Operate the PSEN ma1.3p-22 in conjunction with the following components: Actuator PSEN ma1.3-08 or actuator PSEN ma1.3-12 (see Order reference [...
  • Page 8: Block Diagram

    Block diagram Safety switch Actuator Magnet Operating distances (mm) omin Legend Assured operating distance Min. operating distance omin Assured release distance The offset-independent values for the switching distances are included in the Technical details [ 21]. Operating Manual PSEN ma1.3p-22 22148-EN-05...
  • Page 9: Lateral And Vertical Offset

    Lateral and vertical offset Actuator PSEN ma1.3-08 Legend [1] Lateral offset [2] Vertical offset [3] Sensing faces Assured operating distance S in mm Lateral offset Vertical offset The stated values are valid at a temperature of 20 °C. Operating Manual PSEN ma1.3p-22 22148-EN-05...
  • Page 10 The stated values are valid at a temperature of 20 °C. Negative vertical offset, not permitted Fig.: Safety switch and square actuator - side view Legend [1] Sensing face PSEN ma1.3-12 [2] Positive vertical offset, permitted [3] Negative vertical offset, not permitted Operating Manual PSEN ma1.3p-22 | 10 22148-EN-05...
  • Page 11: Wiring

    Pin assignment NOTICE The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory The safety switch is shown in an unoperated condition. pink Assignment of...
  • Page 12: Requirements And Connection To Evaluation Devices

    PNOZmulti units – may not be used for safety circuits Requirements and connection to evaluation devices For use of PSEN ma1.3p-22 in accordance with DIN EN 60947-5-3 an evaluation device must be connected. Connect the PSEN ma1.3p-22 either with a certified Pilz evaluation device...
  • Page 13 [ of PSEN ma1.3p-22 – Always comply with the max. switching current safety contacts of PSEN ma1.3p-22. Outputs at the evaluation device must only be switched on again when both reed con- tacts at the safety switch have been opened and closed (partial operation lock)
  • Page 14 32 41 11 12 21 22 33 34 43 44 PSENmag Fig.: Dual-channel connection of four PSENmag to the input circuits of an evaluation device Examples for connection to Pilz evaluation devices: PNOZ s3 PSEN ix1 PSENmag White Yellow Pink Green Operating Manual PSEN ma1.3p-22...
  • Page 15: Installation

    The unit can be installed in any position. Safety switches and actuators must be installed so that the bevelled surface on the safety switch and the bevelled surface of the actuator face each other precisely. Operating Manual PSEN ma1.3p-22 | 15 22148-EN-05...
  • Page 16 Please note the installation measures in accordance with EN ISO 14119 for a proximity switch type 4 with coding level Low. Alignment errors of the guard must not adversely affect the safety function of the guard. Operating Manual PSEN ma1.3p-22 | 16 22148-EN-05...
  • Page 17 The protection type (see Technical details [ 21]) can only be achieved by using the Pilz connection leads available as an accessory. Installation of safety switch Slide the switch through the hole in the mounting surface with the sensing face to- wards the actuator.
  • Page 18: Adjustment

    Technical details [ 21]). Adjustment The safety switch may only be used with the corresponding actuator PSEN ma1.3-08 or PSEN ma1.3-12. Always test the function with the PSEN ix1 interface and connected evaluation device. Operating Manual PSEN ma1.3p-22 | 18 22148-EN-05...
  • Page 19: Periodic Test

    Always test the function with the PSEN ix1 interface and connected evaluation device. The safety function may only be checked by qualified personnel. Dimensions in mm Safety switch 26,8 42,6 12,5 33,9 59,1 200 ±10 Actuator PSEN ma1.3-08 Actuator PSEN ma1.3-12 Operating Manual PSEN ma1.3p-22 | 19 22148-EN-05...
  • Page 20 PSEN ma1.3p-22 2xø4,5 Fig.: Actuator holder Operating Manual PSEN ma1.3p-22 | 20 22148-EN-05...
  • Page 21: Technical Details

    EN 60947-5-3 Vibration In accordance with the standard EN 60947-5-2 EN 60947-5-2 Frequency 10 - 55 Hz 10 - 55 Hz Amplitude 1 mm 1 mm Shock stress Acceleration Duration 11 ms 11 ms Operating Manual PSEN ma1.3p-22 | 21 22148-EN-05...
  • Page 22 25 mm 25 mm Weight of safety switch 20 g 20 g 11 g 11 g Weight of actuator Weight 30 g 30 g Where standards are undated, the 2015-09 latest editions shall apply. Operating Manual PSEN ma1.3p-22 | 22 22148-EN-05...
  • Page 23: Safety Characteristic Data

    PSEN cable M8-8sf, 10 m M 8, 8-pin fe- 533 152 male con- nector, straight PSEN cable M8-8sf, 20 m M 8, 8-pin fe- 533 153 male con- nector, straight Operating Manual PSEN ma1.3p-22 | 23 22148-EN-05...
  • Page 24: Ec Declaration Of Conformity

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Authorised representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany Operating Manual PSEN ma1.3p-22...