BRINKS BHS-4000A Installation And Programming Instructions page 4

Table of Contents

Advertisement

BHS-4000A Installation and Programming Instructions
2.1.6 Mounting the keypad
The keypad is mounted on the wall in any convenient interior
location. The keypad should be mounted at a height that is
convenient for viewing by the end user. To mount the keypad,
follow the directions listed below.
1.
Open the keypad housing by depressing the latches at the
base of the keypad with a flat-head screwdriver.
2.
Remove the rear cover
3.
Holding the rear cover level against the wall, mark the
locations of the mounting and wire-entry holes.
Mark the mounting and wire-entry holes
4.
Drill the mounting holes and wire entry holes.
5.
Attach the rear cover to the wall using #8 screws, (not
provided).
6.
Snap the front of the keypad onto the rear cover.
2.1.7 Cover unused emergency keys
____
Cover any unused emergency keys with the plastic key covers.
These covers are distributed in separate packages (P/N 5-531-
234-00), and are not included with the keypads. Remove the
paper backing from the back of the key cover, and press in place.
2.2 Mount the ZEM
2.2.1 Mounting the ZEM inside the panel enclosure
The Zone Expander Module (ZEM) can be mounted internally or
externally of the BHS-4000A's enclosure. The enclosure can
accommodate one ZEM.
When selecting an external mounting location, do not exceed the
maximum wiring distances listed in the table below.
Installation Type
Maximum Distance (m / ft)
UL Installation
152 m/500 ft
Non-UL Installation
305 m/1000 ft
To install a ZEM inside the panel enclosure, do the following:
1.
Remove the ZEM printed circuit board, as shown.
Remove the PCB
2.
Attach the ZEM mounting bracket to the rear of the
enclosure, as shown below.
Attach mounting bracket to the enclosure
3.
Replace the ZEM circuit board in the mounting bracket.
2.2.2 Mounting the ZEM outside the panel enclosure
Additional modules can be mounted in their individual housings.
To mount an external Zone Expander Module, follow the
directions below:
1.
While you are grounded, remove the ZEM's PCB, as shown
above.
2.
Hold the mounting bracket level against the wail and mark
the mounting hole locations.
3.
Secure the mounting bracket to the wall using #8 screws, not
provided.
4.
Replace the PCB on the mounting bracket.
2.2.3 Addressing the ZEM
The ZEM has 11 pairs of jumper pins, which are used to select
the range of zone inputs. The pins are labeled with the beginning
and ending zone numbers for each available input range.
The jumper is factory-installed on the first pair of pins, indicating
that the input range for the ZEM is zones 9 -16. To change the
input range of the ZEM, disconnect power to the panel, then move
the jumper to the set of pins with the appropriate zone numbers.
9-16
17-24
25-32
33-40
41-48
49-56
57-64
65-72
73-80
81-88
89-96
Move jumper to address the ZEM
2.3 Mounting the speakers and siren
Mount the system's speaker(s) and the external siren or bell in
accordance with the manufacturer's instructions.
Jumper
*■
r:

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents