BRINKS BHS-4000A Installation And Programming Instructions page 16

Table of Contents

Advertisement

BHS-4000A Installation and Programming Instructions
Blinking LED
Message
Correction
3
Trouble on fire
zone.
If the trouble follows a
canceled fire alarm, allow
time for any smoke particles
to disperse. Replace the
detector, if necessary.
4
Call Brink's at 1
(800) 445-0872.
Call Brink's Customer Care.
5
Device supervisory
problem.
A wiring
problem exists.
Verify the wire connections.
Replace any defective wires.
Replace device or panel, as
necessary.
6
Siren supervisory
failure.
A wiring
problem exists.
Verify the wire connections.
Replace any defective wires.
Replace siren or panel, as
necessary.
8
Line cut.
The
telephone line has
been cut, or service
is interrupted.
Hang up all telephones. If the
telephone service is
interrupted, instruct the
customer to call the
telephone company.
To identify whether the ninth condition exists, press the OPTIONS
+ 9 keys again. If the zone LED 1 is lit, a Host failure has
occurred.
1
Host failure.
The
control panel could
not complete a call
to the Downloaded
Verify the telephone service
is working. Verify the panel
programming. Verify wiring
connections. Replace any
defective wires. Replace
control panel, if necessary.
2
AC Failure.
The AC
power to the panel is
interrupted.
Check to ensure the panel is
plugged in. Check for broken
or loose wires. Is power out
in the rest of the house? If
not, check the circuit breaker.
If AC is present across terminal
1 and 2, then replace control
panel.