BHS-4000A Installation and Proqramminq Instructions
IMPORTANT
Please read and fully understand the BHS-4000A user's manual before reading this
manual or attempting to install the system.
The user's manual describes the system's features, functions, and user interface
requirements in great detail. That information is
not
repeated in this manual.
2 Mounting
2.1.1 Choose a mounting location for the panel
Choose a mounting location that is:
accessible to both AC power and telephone service
protected from excessive heat or cold and
away from large metal objects, like heating ducts
2.1.2 Remove wiring knockouts
The BHS-4000A enclosure has eight circular wiring knockouts.
These knockouts are located at the sides and back of the
enclosure as shown below.
Eight wiring knockouts
The knockouts can be easily removed using your fingers.
2.1.3 Mounting the panel enclosure
Secure the panel enclosure to the wall as outlined below:
1.
Remove the main PCB before mounting the housing.
2.
Using the base of the housing as a template, mark the
mounting holes (top and bottom) and the wire-entry
holes.
3.
Drill the top mounting holes and wire entry holes.
4.
Insert the top mounting screws, but do not tighten.
(Mount the panel using #10 square-drive screws, not
provided.)
5.
Temporarily hang the enclosure and verify the location
of the lower mounting holes.
6.
Drill the lower mounting holes and replace the
enclosure.
2.1.4 Mounting the panel for commercial installations
When installing the panel in a commercial environment, additional
steps must be taken, as outlined below.
1.
The Bell Wiring must use the upper left-hand knockout and
be enclosed in conduit (#1 in the diagram above right).
2.
All other wiring must use the lower right-hand knockout with
the conduit being optional (#2 in diagram).
3.
All unused knockouts must be removed and covered with
cap bolts (provided).
t
2
Mounting commercial
installing the door lock
enclosure
4.
Install the tamper switch, provided in the kit (#4 in diagram
above) and connect it to a zone input on the panel.
5.
Secure the door with the key lock provided in the kit.
2.1.5 Install the panel's main PCB
Re-install the panel's main printed circuit board as outlined below:
1.
Place the PCB in the enclosure as shown.
2.
Screw the PCB in place using #7 x.^" self-tapping screws
and star washers (provided).
3.
After mounting, secure the cover with #7 sheet meta! screws
(provided) or separate lock (not provided).
Mounting the PCB
Installing the mounting clip
Match PCB to mounting standoffs